Paradox PRT3 Manual

Paradox PRT3 Manual

V2 proxy security driver

Advertisement

Quick Links

Driver:
Paradox PRT3 V2 Proxy Security Driver
Compatible Control4 Systems:
Compatible Paradox Security Systems:
Control Platform:
Change Log:

See Website for changelog

Driver Overview:

Driver uses the new Control4 V2 security proxy including the history agent.

Driver Features:


Reliable RS232 communication with Paradox

Arm security panel (Stay, Away, Instant, Force arm modes)

Disarm security panel

4 and 6-digit user codes supported

RFID integration (using Paradox Door modules), Access Control integration

Multi partition support

Arm or Disarm all partitions easily from Control4 interfaces

MyHome, iPad, iPhone, Android, Control4 GUI supported

Zone labels and usernames are downloaded into Control4 system from Paradox panel

Custom Entry and Exit delay modes

Multi Lingual (English, Czech, Portuguese-Brazil, French, Italian)

Polling Timer for Driver communication verification

Automatic email and text notification of Arm, disarm and alarms of security system. (requires 4Sight)

Driver verifies zone state upon reboot of Control4 (no more issue where 'all zones open').

Utility key support (trigger events in Paradox from Control4 GUI)

Designed for Dealers (Lots of extra events and actions for Control4 programming)

Virtual Input support (Create 'zones' on the paradox that are open and closed via Control4 programming)

Automatically flash the lights when the alarm goes off.

Description of Items in Driver

Property List (System Design)
2.8.2+
RS232
Cinegration has developed a complete security driver for the Paradox PRT3 module.
EVOHD, DigiPlex, any panel using PRT3 module

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRT3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Paradox PRT3

  • Page 1  Designed for Dealers (Lots of extra events and actions for Control4 programming)  Virtual Input support (Create ‘zones’ on the paradox that are open and closed via Control4 programming)  Automatically flash the lights when the alarm goes off.
  • Page 2 Debug will turn off automatically after 15 minutes  Polling Timer (default: 120) Time (in seconds) the driver checks in with the Paradox for RS232 communication Values can be: 0 - 1500 Seconds. 0 = Polling Timer disabled  Number of Zones (default: 0) Required for driver setup.
  • Page 3 Used to download the area labels that are stored in the PRT3 module.  Download Zone Labels Used to download the zone labels for each zone that is stored in the PRT3 module  Download User Labels Used to download the user labels that are stored in the PRT3 module ...
  • Page 4 ‘tell’ Control4 the properties for each zone (see Zone Properties) for more information. Zone Properties (System Design, Top of Screen) Each zone in the paradox system is listed on this page. Double clicking on each zone will list it’s current properties. Below is a description of each.
  • Page 5  Save Settings Special Notes/Tips: Make sure that the PRT3 module has all the correct Usernames, Zone Labels and area names you need. The driver downloads these items automatically saving you the hassle of doing it on the Control4! Control4 Setup ...
  • Page 6 Cinegration has added in the support to download Area, Zone and User label data from the Paradox system. To download, go to actions, and press the corresponding download label that you want. Note: This may take extra time depending on the number of zones or users the panel has.
  • Page 7 About Driver Notes:  This driver contains code written by Cinegration. Any modification to this driver or any driver written by Cinegration without the express consent will void all warranties, constitute a ban on all drivers released by Cinegration and potentially legal action. ...

Table of Contents