Cd Test Mode - Pioneer DEH-X7600S Service Manual

Cd rds receiver
Hide thumbs Also See for DEH-X7600S:
Table of Contents

Advertisement

1

6.2 CD TEST MODE

- Flow Chart
A
To enter the test mode: [EJECT] + [BAND] -> BUP + ACC ON
Operate with a Remote Control with 1 - 6 keys for a CD Receiver in the test mode.
[CD] or [SOURCE]
TRK
[BAND]
(T.Offset is adjusted)
TRK
00 00 00
B
[BAND]
[3]
Power Off
Focus Close
S curve check
TRK
MIN
SEC
TRK
91 91 91
[BAND]
[1]
T.Close & AGC
Power Off
Applicable servomechanism
TRK
MIN
SEC
TRK
?tr ?min ?sec
[BAND]
[1]
Power Off
F,T,RF AGC
F.Bias display switching
C
TRK
MIN
SEC
TRK
??
[BAND]
Power Off
TRK
MIN
SEC
t
*1)
TYP
TRK
MIN
SEC
D
t
*2) Focus Close
S. Curve
TRK
MIN
SEC
TRK
00
00
00
01
TRK
MIN
SEC
(
99
99
99)
*3) F.Offset Display t
RF.Offset
*4) 100TR Jump
*5) TRK/MIN/SEC t F.AGC t T.AGC Gain t F.Bias t RF AGC
E
*6) CRG motor voltage = 2 [V]
After the [EJECT] key is pressed keys other than the [EJECT] key should not be pressed, until disc ejection is complete.
When the key [UP] or [DOWN] is pressed during the Focus Search, the power supply should be immediately turned off (otherwise the
lens sticks to Wall, causing the actuator to be damaged).
In the case of 100TR Jump, the mechanism shall be set to the Tracking Close mode when the key is released.
When the power is turned on/off the gain of the RFAMP is reset to 0 dB. At the same time all the self-adjusting values shall return to the
default setting.
F
Do not do Tracking Servo Close before doing Focus Servo Close. (Because the overcurrent flows)
24
1
2
Source ON
MIN
[2]
Power On
Gain switching
MIN
SEC
TRK
GG
[6]
[1]
Focus Mode switching
Tracking Servo
*2
MIN
SEC
TRK
MIN
SEC
00 00 00
0X
0X
0X
or 99 99 99
[3]
RF AGC coefficient display
MIN
SEC
TRK
??
[3]
*5
F,T AGC / F.Bias
RF AGC
MIN
SEC
TRK
MIN
SEC
??
??
?tr ?min ?sec
t
+ 6 dB
+ 12 dB
TRK
MIN
SEC
TRK
MIN
06
06
06
12
12
t
F EQ measurement setting
MIN
SEC
TRK
MIN
01
01
02
02
t T.Offset Display t
Switch to the order
of the original
display
DEH-X7600S/XNUC
2
3
[Key]
Contents
Display
*1
RF AMP
MIN
SEC
GG
GG
[UP]
[DOWN]
CRG +
Close
*6
00 00 00
00 00 00
or 99 99 99
or 99 99 99
[UP]
[DOWN]
RF AGC /
CRG +
MIN
SEC
8X 8X 8X
8X 8X 8X
??
??
or 9X 9X 9X
or 9X 9X 9X
[UP]
[DOWN]
CRG/TR Jump +
CRG/TR Jump -
*4
TRK
MIN
SEC
TRK
?tr ?min ?sec
?tr ?min ?sec
[2]
Tracking Open
8X 8X 8X
or 9X 9X 9X
[Key]
SEC
12
[BAND]
Power On/Off
CRG + / TR Jump +
[UP]
(Direction of the external surface)
[DOWN] CRG - / TR Jump -
SEC
(Direction of the internal surface)
02
[1]
T. CLS & AGC & Applicable servomechanism /
AGC,AGC display setting
[2]
RF Gain switching / Offset adjustment display /
T.Balance adjustment / T. Open
[3]
F. Close,S. Curve / Rough Servo and RF AGC /
F,T,RF AGC
[6]
F. Mode switching / Tracking Close
3
[2]
CRG -
Self-adjusting
*6
switching
*3
TRK
MIN
SEC
??
??
??
[2]
CRG -
T.Balance adjustment /
T.BAL coefficient display
TRK
MIN
SEC
??
??
??
[2]
Tracking Open
*4
MIN
SEC
8X 8X 8X
or 9X 9X 9X
*6
Operation
Test Mode
4
4

Advertisement

Table of Contents
loading

Table of Contents