Connecting The Cable Between Indoor Unit And Outdoor Unit; Connect The Cable - LG LSN090CE Service Manual

Lg room air conditioner service manual
Hide thumbs Also See for LSN090CE:
Table of Contents

Advertisement

Connection Of The Cable
1. Remove the cover control from the unit
by loosening the 3 screws.
2. Dismount caps on the conduit panel.
3. Temporarily mount the conduit tubes
on the conduit panel.
4. Properly connect both the power sup-
ply and low voltage lines to the corre-
sponding terminals on the terminal
block.
5. Ground the unit in accordance with
local codes.
6. Be sure to size each wire allowing sev-
eral inches longer than the required
length for wiring.
7. Use lock nuts to secure the conduit
tubes.
NOTICE
Connector trade size for this unit is 1/2" for
instructions on connecting depending on
the wire type you are using.
• Be sure to comply with local codes while
running the wire from the indoor unit to
the outdoor unit(size of wire and wiring
method, etc).
• Every wire must be connected firmly.
• No wire should be allowed to touch refrig-
erant tubing, the compressor or any mov-
ing parts.
Power Supply
AWG(MIN.)
Model Power source
9K
1ø, 115V
14
12K
1ø, 115V
14
18K
1ø, 230/208V 14
24K
1ø, 230/208V 12
Fuse or breaker
Capacity
18
15A
18
20A
18
20A
18
25A
Wiring Diagram
Connecting cable(Low voltage) b
Indoor Unit
Outdoor Unit
Terminal
Terminal
(4P)
(6P)
1
1
2
2
3
3
4
4
5
*
L1
6
L2
G
L1 is neutral for 115V models.
*
NOTICE
1.
shows field wiring.
2. Separately wire the high and low voltage line.
3. Use heat-proof electrical wiring capable of
withstanding temperatures up to 167°F.
4. Use outdoor and waterproof connection cable
rated more than 300V for the connection
between indoor and outdoor unit.
(For example, Type STOW)
Outdoor unit
Terminal block
Over 5mm
(0.2")
Cover control
Power supply a
To
branch
circuit
Ground
Conduit panel
Connecting
cable
Power supply
cord
Service Manual 27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents