Select The Best Location

Indoor unit

1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in
front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the space around the left and right
of the unit is more than 30cm(11.8in). The unit
should be installed as high on the wall as possi-
ble, allowing a minimum of 12cm(4.7in) from
ceiling.
Install the indoor unit on the wall where the height from the floors more than 2.3meters(7.6ft).
A minimum pipe run of 7.5meters(24.6ft) is required to minimize vibration and excessive noise.
Outdoor unit
1. If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not
restricted.
2. Ensure that the space around the back and
sides is more than 10cm(3.9in). The front of the
unit should have more than 70cm(27.6in) of
space.
3. Do not place animals and plants in the path of
the warm air.
4. Take the air conditioner weight into account and
select a place where noise and vibration are
minimum.

Rooftop Installations

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and
anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or walls, this may result in excessive noise and vibra-
tion, and may be also classed as non serviceable installation.
6. Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
More than
30cm(11.8in)
More than 8ft(2.4m)
5. Select a place so that the warm air and noise
from the air conditioner do not disturb neigh-
bors.
More than
10cm(3.9in)
More than
70cm(27.6in)
More than
12cm(4.7in)
More than
30cm(11.8in)
More than
60cm(23.6in)
More than
10cm(3.9in)
More than
60cm(23.6in)