3) Preparing work for Installation
1. Open panel front
First,Pull the grille bottom, then remove screws(2
pieces), and close grille bottom again.
The moment of lifting the both lower parts of panel
front, you can hear sound this panel came out, In
this time panel front is separated
After pull down this panel a bit, and separate con-
necting wire with product.
Panel Front
Connector
2. Cover pipe and cover side remove
Remove two screws(for fixing cover pipe)
Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
In case connecting direction is left or right, path
through the hole of cover side.
CAUTION
After removing the pipe hole, cut the burr for safety.
Pipe hole
Side cover
When connecting pipe path through rear wall, don't
remove the hole.
3. Drain hose junction
Remove the rubber stopple of desired drain direc-
tion.
As the following picture, Insert drain hose in the
handle of drain pan, and join drain hose and con-
necting hose.
Adhesive
Connecting
part
Drain
hose
Installation
Only one
desiring direction
rubber cap
Service Manual 29