Standard Horizontal Installation Confi gurations
Profi le
®
20 FS-2 and Profi le 30 FS-2
3" (75 mm) Minimum
clearance between
wall and pipe. If you
vent to the furthest
wall, the vent pipe
must maintain a 3"
clearance parallel to
the other wall.
2" Min.
Wall
Figure 22 - Corner Through the Wall, Profi le 30 FS-2*
6" / 152 mm
Minimum
Figure 24 - Parallel Through the Wall, Profi le 20 FS and Profi le 30 FS
* Note: Horizontal run of pipe requires 1/4" (7 mm) rise per foot.
Top View Illustration
2" Min.
Wall
Hearth Pad / Floor Protection
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
3" (75 mm) Minimum
clearance between wall
and pipe. If you vent to
the furthest wall, the vent
pipe must maintain a 3"
clearance parallel to the
other wall.
2" Min.
Wall
Figure 23 - Corner Through the Wall, Profi le 20 FS-2*
2" / 51 mm
Minimum
Wall
Top View Illustration
Top View Illustration
2" Min.
Wall
Outdoors
45 Degree
Elbow
12" (305 mm)
Minimum From
Outer Wall
12" / 305 mm From
Ground or Other Surface
15