IMPORTANT: The probe length value entered must be accurate to <2.5 cm (1 in).
End of probe
• To improve performance and minimize the size of the dead zone, we recommend using the puck-
shaped weight (height: 2.5 cm [1 in], diameter: 7.3 cm [2 7/8 in]) (ABB order code QP6).
• Use "long" weights ONLY if the diameter of the vessel top opening does not allow you to use of the
puck-shaped version.
Configuring instrument for oil & gas applications
The following parameters need to be configured specifically for oil & gas applications. Configuration of
these parameters is explained in more detail in the LWT300 User Guide:
• Type of application (in the
on page 4 of this document).
– (If the application category selected is
oil on top of water), you must set the dielectric constant (DC) of the first liquid that the pulse will
encounter (in this case, oil) in the
"Setting the dielectric constant of upper media" in the LWT300 User Guide). (Appendix D of the
LWT300 User Guide contains a list of dielectric constants for common substances).
• Calibration parameters (
menu) (for details, see Figure 5 below.)
Calibration
Figure 5
Calibration parameters
Sensor
reference
Full/Span
Empty/Zero
Probe length
Easy Setup > Application Category
Interface
Device Setup > Sensor Setup > Upper Media DC
,
Empty/Zero
Full/Span
Ullage
Level
menu) (see "Application Category"
(to measure the interface between liquids, e.g.,
,
) (in the
Level Offset
Distance
Level offset
LWT300 series (Modbus) Quick Start Guide
menu (see
Calibrate > Level > Level
+ sensor offset