6. The SCD displays a flashing
If no error is detected, the diagnostic test loops and begin again. To stop the loop, press Unload for 1 second and release. When the loop ends,
temporarily displays in the SCD, and the tape drive exits Maintenance mode.
If an error is detected, the Fault light flashes and the drive posts an error code to the SCD. To determine the error, locate the code in
the error either turn the power off and then on again, or reboot the drive by pressing and holding Unload for 10 seconds.
1
Note:
Not supported on the USB port.
Function code 7: Run RS-422 wrap test
Note: This function is described here for information only. It is not supported on the IBM® TS2260, TS2270, or the TS2280 tape drive.
This test causes the drive to process a check of the circuitry and connector for the RS-422 interface. This connector supports the Library Drive Interface (LDI) and
the Automation Drive Interface (ADI).
Before this function is selected, attach an LDI or RS-422 wrap plug to the drive 's LDI or RS-422 connector (in place of the LDI or RS-422 cable).
1. Make sure that no cartridge is in the drive, and the appropriate wrap plug is attached to the RS-422 connector.
2. Place the drive in Maintenance mode. For instructions, see
3. Press Unload once per second until
displayed again.
4. To select the function, press and hold Unload for 3 seconds. After you select the function,
If no error is detected, the diagnostic test loops and begin again. To stop the loop, press Unload for 1 second and release. When the loop ends,
temporarily displays in the SCD, and the tape drive exits Maintenance mode.
If an error is detected, the Fault light flashes and the drive posts an error code to the SCD. To determine the error, locate the code in
the error either turn the power off and then on again, or reboot the drive by pressing and holding Unload for 10 seconds.
Function code 8: Unmake FMR tape
Function code
erases the field microcode replacement (FMR) data and rewrites the cartridge memory on the tape. This action converts the cartridge into a valid
scratch (blank) data cartridge.
1. Place the drive in Maintenance mode. For instructions, see
2. Press Unload once per second until
3. Press and hold Unload for 3 or more seconds, then release it to select function
4. Insert the FMR data cartridge (or the tape drive exits Maintenance mode). The SCD changes to a flashing
and rewrites the header in the cartridge memory to change the cartridge to a valid scratch (blank) data cartridge: The drive then ejects the cartridge and
exits Maintenance mode.
Note: If you inserted an invalid tape cartridge, error code
compatibility, error code
removed.
If the tape drive creates the scratch tape successfully, it rewinds and unloads the new tape, exits Maintenance mode, and the tape is ready to use.
If the tape drive fails to create the scratch tape, it displays an error code. To determine the error, see
tape, and exits Maintenance mode after the cartridge is removed.
Function code 9: Display error code log
Function code
displays the last 10 error codes, one at a time (the codes are ordered; the most recent is presented first and the oldest is presented last). If there
are no errors in the log, function code
1. Place the drive in Maintenance mode. For instructions, see
2. Press Unload once per second until
3. Press and hold Unload, then release it to view the most recent error code.
4. Press and release Unload again to view successive error codes. Allow 2 - 3 seconds pass between each depression. The Ready light and Fault light flash
On/Off once for each successive error code. The SCD displays
5. After all error codes are viewed, exit this function by pressing Unload again. The SCD displays
Function code A: Clear error code log
Function code
erases the contents of the error code log.
1. Place the drive in Maintenance mode. For instructions, see
2. Press Unload once per second until
96 IBM TS22xx Tape Drives
during the test.
2
Not supported on the SAS/USB drive.
Entering Maintenance
appears in the Single-character Display (SCD). If you cycle past
Entering Maintenance
appears in the SCD. (If you cycle past the wanted code, press Unload once per second until the code reappears.)
or
appears in the SCD. In either case, the tape drive unloads the cartridge and exits Maintenance mode after the cartridge is
displays in the Single-character Display (SCD) and exits Maintenance mode.
Entering Maintenance
appears in the SCD. (If you cycle past the wanted code, press Unload once per second until the code reappears.)
Entering Maintenance
displays in the SCD. (If you cycle past the wanted code, press Unload once per second until the code reappears.)
mode.
flashes and the drive automatically starts the test.
mode.
. The SCD changes to a flashing
appears in the SCD. If you inserted a write-protected cartridge, or the media has read-only
mode.
when all the error codes are displayed.
and exits Maintenance mode.
mode.
Table
, continue to press Unload until the code is
Table
, requesting a cartridge.
. The tape drive erases the firmware on the tape
Table
1. The tape drive then unloads the FMR
1. To clear
1. To clear