Tube system elements
Fig. B Description
1
Hose (2 pcs)
2
Attachment clip with suction cup (6 pcs)
3
U-piece inlet
4
Telescopic tube
5
Suction sieve
6
Foam pre-filter
7
U-piece outlet
8
Nozzle tube
9
Nozzle end tube (with sealing plug)

OPERATION

Switching on and off
The device is switched on when the plug is inserted into a socket. It is switched
off (no power) when the plug is pulled out.
Controls
Fig. C
Description
1
Shut-off lever
Position up: Shut-off valve open. Water circulation on.
Position down: Shut-off valve closed. Water circulation off.
Position bottom right: The hose adapter is unlocked and can be
removed upwards.
2
Stopcocks
The flow rate can be adjusted using the IN stopcock (inlet). The
OUT stopcock (outlet) should always be fully open when the filter
is in use.
3
Start button
If there is no (or very little) water in the filter housing, the filter
pump cannot generate a flow of water. If you press the start button
several times, water is pumped into the filter housing and the filter
is vented.