Communication modules, interface modules for the ec1000 (24 pages)
Summary of Contents for BERGHOF B-Nimis MC-Pi Series
Page 1
USER MANUAL 1.2 B-Nimis MC-Pi and BC-Pi series...
Page 2
You can contact us at: Berghof Automation GmbH Arbachtalstrasse 26 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-100 Email: controls@berghof.com www.berghof-automation.com Berghof Automation GmbH is certified to DIN EN ISO 9001:2015. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 3
USER MANUAL 1.2 | B-NIMIS MC-PI AND BC-PI SERIES Revision log Version Date Description 16/11/2021 Preliminary version 06/12/2021 Review version 17/12/2021 Release Version Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
List of instructions which must be carried out in the order given. … Additional product information Structure of the warnings: WARNING Optional: Type and source of the danger More Brief description and consequences symbols Preventive measures Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
→ The user is responsible for coordinating the use of the safety-related control components with the responsible authority and for adhering to its specifications. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Wait at least 12 hours after it has reached room temperature before operating the device. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The documentation supplied contains important information about the unit and is part of the product. If you notice transport damage or discrepancies between the order and the delivered con- tents: Inform the supplier immediately. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Do not open the device housing. If it is necessary to work on internal parts of the device, contact the manufacturer (see “Customer services / addresses”). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Use the security mechanisms of VPN server portals (e.g. IXON) to which the controller can actively connect via VPN or comparable mechanisms. Use https instead of http Disable the services you do not need, such as (FTP/SSH/Webserver). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
2 x USB 3.0 2 x USB 3.0 Gbit LAN 100 Mbit LAN USB 2.0 / Boot 100 Mbit LAN Connector for antenna Micro SD Debug Reset Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
EN 61000-6-4, industrial zone Resistance to EN 61000-6-2, industrial areas interference Protection class Insulation resistance SELV (Uw < 30 V) acc. to EN 61131-2 Protection rating IP20 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
EN 61000-6-4, industrial zone Resistance to EN 61000-6-2, industrial areas Interference Protection class Insulation resistance SELV (Uw < 30 V) acc to EN 61131-2 Protection rating IP20 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
EN 61000-6-4, industrial zone Resistance to EN 61000-6-2, industrial areas interference Protection class Insulation resistance SELV (Uw < 30 V) acc. to EN 61131-2 Protection rating IP20 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
HDMI 1.4 standard, with a corresponding connection for the con- nected monitor. Visualisation CODESYS web visualisation is included with the MC-Pi. An easy-to-use display is available with the Berghof B-Primis ET terminals. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 21
1 EtherCAT LVDS interface with up to 10 nodes on the LVDS bus (or max. 2 A load) → 1x real-time clock (RTC), (buffer time 72h) → 1x µSD card slot → 1x display interface → 1x fan connection (+5V) Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
After snapping the first module onto the rail, snap on the second module about 1 cm away, to the right of the first module. Push the second module along the rail towards the first module until the release latch snaps into place. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 23
Turn the module forwards away from the mounting rail as shown in the illus- tration. → Pull the module down off the mounting rail. Fig.: 4 Disconnecting the B-Nimis MC-Pi & BC-Pi Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The supply lines must be sufficiently resilient to current and voltage. Shielded lines must be used for communication. The shield must be connected to the mod- ule. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
GND The following counterparts have been tested for the SL-SMT 3.5 plug-in connector (Weidmüller), and may be used with the device: → BLZF 3.5/03/180 (F,LR,LH) SN Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Connect functional earth Fig.: 5 Earthing NOTICE Earth wires should be short and have a large surface area (copper braiding). You can find information, for example, at http://de.wikipedia.org/wiki/Masse_(Electronics). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Devices with a USB interface can be connected to the USB host port (Rev. 2.0). Suitable USB de- vice classes for CODESYS users are USB thumb drives only. Pin assignment B1 B2 B3 B4 Connector Function Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 29
The X represents a number from 1 (first USB device) to 8 (last/max. USB device). The mechanical construction of the USB interface is designed for up to 1000 plugging cycles. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The device does not have an on/off switch. The device starts automatically when the system is switched on or the power is connected. Switching off The device is switched off when the system is switched off or the power supply is disconnected. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The login window is displayed. Fig.: 7 Login window Log in with the following login information: Name: admin Password: admin The web configuration page will be displayed. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 33
Save the settings by clicking on “Save”. Additional settings can also be viewed and/or modified on the web configuration page (e.g. “Sys- tem time”, display resolution, TargetVisu). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 34
Click on “Reboot” in the web interface and then confirm on the next page by clicking on “Reboot Module”. The device is configured and ready for use. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Change to maintenance mode CODESYS SPS Short press Change between RUN and STOP mode of the PLC Long press Stop the PLC with RESET of variables (cold reset) Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Page 36
Carry out a reset on the device, alternatively: Mode-selection switch / CODESYS/ web browser → Put the controller back into operation Ethernet status LED See section: 10/100 Base-T network connection (Ethernet). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The operating life of the gold-plated contacts is up to 10,000 plugging and unplugging cycles. The SD card drive has a push-in/push-out insertion and ejection mechanism. To avoid malfunction, the SD card may not be removed by pulling. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The controller must be switched off to enter service mode. The button is then held down and the controller is switched on again. The button must be kept pressed until the Run/Stop LED flashes yellow every two seconds. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Correct the network settings and make a note of them. Restart the device. Maintenance mode is turned off automatically. The device is configured and ready for use. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Make sure all the ventilation openings are kept free of obstructions Do not open the device. If it is necessary to work in the device, contact the Service depart- ment. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Turn the module forwards away from the mounting rail as shown in the illustration. Pull the module down off the mounting rail. Releaselatch Fig.: 11 Disassembling the B-Nimis MC-Pi & BC-Pi Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Dispose of electronic scrap in accordance with the national laws and regulations. Make sure that the battery is completely discharged. Dispose of batteries at a recognised collection point in accordance with national laws and regulations. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
QR code (identification no.) Serial number of the unit Version identification CE marking Logo of the manufacturer MAC addresses of the unit Default password Fig.: 12 Type plate Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Products ➔ Modular controllers ➔ B Nimis MC-Pi & BC-Pi ➔ Declaration of Conformity A link to download the Declaration of Conformity can be found on the product page: Fig.: 14 Download menu for technical data from home page Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
The source code will be sent to the given address after reimbursement of the expenses actually incurred for providing the data carrier and shipping. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | Germany | www.berghof-automation.com...
Need help?
Do you have a question about the B-Nimis MC-Pi Series and is the answer not in the manual?
Questions and answers