BERGHOF EC-COM User Manual

Communication modules, interface modules for the ec1000

Advertisement

Quick Links

USER MANUAL 1.0
EC-COM Communication Modules
Interface modules for the EC1000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EC-COM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BERGHOF EC-COM

  • Page 1 USER MANUAL 1.0 EC-COM Communication Modules Interface modules for the EC1000...
  • Page 2 This equipment manual is only complete in conjunction with the product-related hardware and software user  Completeness manuals required for the individual application. You can reach us at: Berghof Automationstechnik GmbH Harretstr. 1 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-100 e-mail: controls@berghof.com www.berghof.com Berghof Automationstechnik GmbH works in accordance with DIN EN ISO 9001:2000.
  • Page 3 USER MANUAL 1.0 | EC-COM COMMUNICATION MODULES Update Version Date Subject 20.06.2013 First Version Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 4 USER MANUAL 1.0 | EC-COM COMMUNICATION MODULES Blank page Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 5: Table Of Contents

    Repairs/Service .......................... 21 3.3.1. Warranty ............................21 3.4. Nameplate ..........................22 Nameplate descriptions (example) ....................22 3.5. Addresses and Bibliography ..................... 23 3.5.1. Addresses ........................... 23 3.5.2. Standards/Bibliography ........................ 24 Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 6 USER MANUAL 1.0 | EC-COM COMMUNICATION MODULES Blank page Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 7: General Information

    The manual contains information about the following topics:  Areas of application;  Safety;  Mechanical construction;  Electrical construction;  Connections; Commissioning;  Care and maintenance;  Decommissioning;  Disposal.  Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100185FE01.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 8: Hazard Categories And Terminology

    Part 6-2: Generic standard – immunity for industrial environments DIN EN 61000-6-4:2011-9 Electromagnetic compatibility (EMP)  Part 6-4: Generic standard – electrostatic discharge for industrial environments Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100185FE01.docx...
  • Page 9: Qualified Personnel

     only then switch off the controller and the system and   only now disconnect the controller module from the system. Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100185FE01.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 10: Use As Prescribed

    All types of failure and the associated fuse systems are to be taken into ac- count at system level. The advice of the SPC manufacturer should be sought if necessary. Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100185FE01.docx...
  • Page 11: Product Description

    2VF100595DG00.cdr Mounting The EC-COM communication module is connected to the left face of an EC1000 controller with the integra- ted plug connector. The module is meant for mounting in a switching cabinet and DIN rail installation. The power supply is provided by the EC1000, with provision for a maximum of one communication module on the EC1000.
  • Page 12 CAN high-speed standard (ISO11898) and can be used as CANopen master. Serial interface The serial interface of the EC-COM can be operated either as RS232 or as RS485, making a changeover switch possible. For RS485 operation a terminator may additionally be connected.
  • Page 13: Technical Data

    EN 61000-6-4, industrial Insensitivity to interference EN 61000-6-2, industrial Protection class Protection type IP20 Energy supply Energy supply Via EC1000 CPU Power consumption Typically 0.2 A Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100205FE00.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 14: Block Diagram

    USER MANUAL 1.0 | EC-COM COMMUNICATION MODULES 2.3. Block diagram 2VF100591DG00.VSD Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100205FE00.docx...
  • Page 15: Module View And Pin Assignment Ec-Com 01

    DipSwitch 2VF100592DG00.VSD 2.5. Module view and pin assignment EC-COM 02 EC-COM 02 LAN1 active Connection to EC1000 LAN1 LAN2 active LAN2 COM / Double DipSwitch 2VF100593DG00.VSD Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100205FE00.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 16: Mounting And Connecting

    Push down the unlock button (see figure below) of the EC1000 module that you wish to disconnect from the EC-COM module to the left of it. Push both modules away from one another until they are about 1 cm apart.
  • Page 17: Connecting

    Connect DIN rail with operative earth Aluminium profile NOTICE Earth wires should be short and have a large surface (copper mesh). Further details has site http://en.wikipedia.org/wiki/Ground (electricity). Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100205FE00.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 18: Pin Assignment

    LAN plug-in connector assignment RJ45 75 Ohm 75 Ohm 75 Ohm 75 Ohm “LNK” LED green ON: ready to operate “RCV” LED yellow FLASHING: Data Receive Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100205FE00.docx...
  • Page 19: Can Bus And One Serial Interface

     Dip switch serial interface switch), which is built in between the lateral cooling ope- nings. The serial interface of the EC-COM can be operated either as RS232 or as RS485. A terminating resistor can EC-COM Dip switch additionally be cut in for RS485 operation. The serial inter- RS485 face is addressed in the software under the name of COM2.
  • Page 20 USER MANUAL 1.0 | EC-COM COMMUNICATION MODULES Blank page Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100205FE00.docx...
  • Page 21: Annex

    Sold under statutory warranty conditions. Warranty lapses in the event of unauthorised attempts to repair the equipment and/or product, or in the event of any other form of intervention. Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100055FE04.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 22: Nameplate

    With the latter in mind, before the download you should always keep a record of the existing software levels in your project documentation (software version, node IDs, baud rate, etc.). Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100055FE04.docx...
  • Page 23: Addresses And Bibliography

    D-90482 Nuremberg / Germany info@ethercat.org www.ethercat.org Beuth Verlag GmbH, 10772 Berlin  DIN-EN Standards VDE-Verlag GmbH, 10625 Berlin VDE Verlag GmbH, 10625 Berlin  IEC Standards Internet search: www.iec.ch Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com 2VF100055FE04.docx | EC_COM_HB_en_2D1972000ZD00.docx...
  • Page 24: Standards/Bibliography

    CiA users' or- ganisation. Notice: Our Technical Support team will be glad to provide other literature references on request. Berghof Automationstechnik GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com EC_COM_HB_en_2D1972000ZD00.docx | 2VF100055FE04.docx...