Saunacore Steamcore Pro Series Installation Manual & Owner's Manual

Saunacore Steamcore Pro Series Installation Manual & Owner's Manual

Advertisement

SAUNACORE
INSTALLATION INSTRUCTIONS FOR STEAMCORE STEAM GENERATORS & CONTROLS
INSTALLATION
GUIDE &
OWNERS MANUAL
St e a m c ore Pro-Se rie s
This Manual contains installation and operation instructions,
specifications, maintenance information, and warranty information
SAUNACORE
Technical Hotline 905-951-6662
www.saunacore.com

Advertisement

Table of Contents
loading

Summary of Contents for Saunacore Steamcore Pro Series

  • Page 1 SAUNACORE INSTALLATION INSTRUCTIONS FOR STEAMCORE STEAM GENERATORS & CONTROLS INSTALLATION GUIDE & OWNERS MANUAL St e a m c ore Pro-Se rie s This Manual contains installation and operation instructions, specifications, maintenance information, and warranty information SAUNACORE Technical Hotline 905-951-6662...
  • Page 2 Every single unit is tested for proper operation before leaving our manufacturing plant. When we at Saunacore sat down to create a new steam bath generator, we acted on satisfying our customers wishes for Quality, Safety, Reliability, and Durability. We also made it Strong, Practical, and Powerful, by using the most advanced parts available.
  • Page 3 Generator Installation Instructions STEAMCORE Requirements for Proper Installation 1.) Use copper or brass fittings only. (NEVER USE GALVANIZED Typical Commercial Model FITTINGS) 2.) The water inlet, steam outlet, and drain need brass unions for easy removal. 3.) The Generator must be upright, accessible, and on a level surface. 4.) Unit may be installed up to 50 feet away from shower area.
  • Page 4: Installation Instructions

    Read these instructions before installation or service. Although the Steamcore Steam Bath Generator has been fully qualified for shipment by Saunacore, the following must be reviewed for proper, safe and enjoyable steam bathing. Verify that the model and accessories are correct, including line voltage.
  • Page 5: Steam Room

    Duct should be 100% steam and water tight. Avoid sags in duct which may cause water pockets, that will block outlet, due to NOTE: These are only suggestions. condensation. Saunacore manufactures quality steambath generators and sauna heaters; therefore we cannot warrant information regarding materials and construction...
  • Page 6 Steam Line 50ft+ cubic feet. This case the KWS (9000 watts) Glass Block Wall generator is required. If there is doubt in size, it is recommended to choose the next larger size. Steam Line Subject to Freezing Glass Wall www.saunacore.com...
  • Page 7: General Installation Instructions

    General Installation Instructions (All Steam Bath Units) STEAMCORE Steam Generator Positioning: The steam generator must be properly positioned for it to work. Place the steam generator TOP UP, which will be indicated on the Unit with arrows. The steam line(s) are on the top of the unit. The water inlet, electrical connection box, and drain are on the sides of the unit.
  • Page 8 Where local codes permit, provide a drain line strongly recommended if your steam generator is more than 10 feet from connection from a generator drain valve. Check the steam room. local plumbing code for receptor, trap and vent requirement. Unit drains by gravity. Slope down. www.saunacore.com...
  • Page 9 Maintenance: Saunacore steambath generators are designed for unattended operation and require little maintenance. Other than periodic draining, maintenance procedures are not required. Every 2 months, or more often in "hard" water...
  • Page 10 We always recommend installing a shower in domestic steam rooms. After all, a steam room also makes the best shower room imaginable. And it is so pleasent to cool off with an ivigorating shower now and again during a steam bath. www.saunacore.com...
  • Page 11 General Installation Instructions (All Steam Bath Units) STEAMCORE How to make the most of a steam bath. Most people find that the most comfortable steam bathing temperature is between 40 and 45°C. Use a bimetallic type of thermometer to check the temperature.
  • Page 12: Steam Head Installation

    Typical Residential Plumbing Installation (Elegance Model) STEAMCORE KWS2 - KWS12 Typical Residential Plumping Installation with Elegance Steam Head 1" Steam LIne Add Pressure Valve into Steam Line (use 3 way connection "T") Steam Room 1" Water supply 1" or 1/2" Steam Line Outlet One Elegance Steam Heads 1"...
  • Page 13 1" Steam Lines Six Elegance Steam Heads 1/2" pipe Floor Drain slope down Air Gap Floor 10"-12" Floor Drain Note: All 1" steamlines must split and have 2 steam heads. Total of 2 steam heads per 1" steam outlet. www.saunacore.com...
  • Page 14 This must be done on Residential & Commercial units. A 15 PSI Pressure Relief Valve and coupling has been suppli It must be installed on-site by a qualified licensed plumber Use adequate silicone or tape sealant when threading onto st prevent steam leaks for connections. www.saunacore.com...
  • Page 15: General Installation

    General Installation STEAMCORE 1.) Under NO circumstances is the steam line from the steam generator to be restricted or reduced to less then 1/2” inside diameter, or contain a steam trap. Steam line distance maximum 50 ft. 2.) Under NO circumstance should there be a valve or other obstruction in the steam line.
  • Page 16: Control Installation

    Control Installation STEAMCORE SS I Control L3 G Temperature Sensor (Locate in Steam Shower) NOTE: SS I Control ma y be located inside or outside of the steam room. The SSII control must be installed in the steam shower. SSII control has the steam shower temperature sensor built into the control keypad. Main power supply in conduit or use bx (L1, L2, L3, and Ground.) SSI CONTROL 1.
  • Page 17 User Manual Control panel (both SSI and SSII) dimension SSI and SSII Control panel may be switched for Spa II 160mm 70mm 23mm S S I 25mm 113mm 75mm S S I I...
  • Page 18 User Manual Installation instruction of controller Before installing the controller, make sure the steam generator is shut off Important: otherwise the controller may be damaged. Step one Determine the installation location of the controller. The controller is designed to be installed in the steam room : 1.
  • Page 19 User Manual Step five Remove the paper on the b ackside . To achieve good sticking effect, keep the mounting surface clean and dry. Step six L o c a t e t h e d i s p l a y s c r e e n i n t h e Control Panel SS I Control Panel SS II direction of 12 o'clock, and press tight...
  • Page 20: Led Screen

    User Manual Illustration of the controller panel (SS I Control Panel IN/OUT SHOWER USE Power ON/OFF LED SCREEN Steam Time Adjust Key--LOW Power Indicator LED Steam Temperature Adjust Key--LOW Steam Time Adjust Key--HIGH Steam Temperature Adjust Key--HIGH Mood Light Indicator LED Mood Light ON/OFF Steam ON/OFF Operation instruction (SS I...
  • Page 21 User Manual Mood Light When system is activated, press and release button to turn on the mood light. Indicator LED on the right of the button should be lit. Press and release button again to shut down mood light. Steam ON/OFF When unit is powered on, press and release button, water input steam boil tank automatically, press and release...
  • Page 22 User Manual Illustration of the controller panel (SS II Control Panel IN SHOWER USE ONLY Power switch Time set button Time/temperature decrease button Time/temperature increase button Light function button Temperature set button Digital display screen Steamcore The front decorative panel Temperature sensor Control Panel Operation instruction (SS II...
  • Page 23: Time Setting

    User Manual When the actual temperature is smaller than or equal to 32 , the digital tube will display 32 . When the actual temperature is smaller than or equal to 140 , the digital tube will display . The last digit displays as the unit of Fahrenheit temperature.
  • Page 24: Light Function

    User Manual Light function When the machine is started, press button repeatedly to turn on/off light function. When the light is turned on, the digital tube will temporarily display (as is shown in Fig.6). When the light is turned off, the digital tube will temporarily display (as is shown in Fig.7).
  • Page 25 ight Page 25...
  • Page 26 Page 26...
  • Page 27 Wiring Diagram 208V (3PH) Steamcore Ce1g Supply Water Level Sensor To Control Panal Red(Short Pin) Terminal Block Black(Long Pin) Yellow(Middle Pin) Yellow/Green Black Black manual reset hi-limit Black auto reset Blue hi-limit Black Optional Light Brown 12 psi pressure switch (UL - USA Application 18kw & Up) Steamcore 15kW / 18kW (208V - 3PH) Supply Water Level Sensor...
  • Page 28: Technical Specifications

    27000 1125 208V / 3 / 75.0 1” USA & European safety standards. Saunacore reserves the right to 450V / 3 / 34.7 change, alter or discontinue models. Items and colors may not be 575V / 3 / 27.1 exactly as shown. Sizes are approximate. Not liable for any misprint.
  • Page 29: Troubleshooting

    Cause: The w ater is no t reaching the st eam generat or. Solution: Open the tap(s) connect ed to the piping t o allow incoming w ater to flow into the st eam generat or. 3 3 3 www.saunacore.com...
  • Page 30 User Manual Common trouble shooting methods To facilitate your use and maintenance of sauna room, the following common trouble shooting methods are listed for reference. Causes of troubles Trouble-shooting methods Troubles 1.The fuse is burned. 1.Change the fuse (on the shell 0.8A/ 2.The wire connection terminal The machine 250V)
  • Page 31 Warranty applies only to the original consumer purchaser, warranty is non-transferable. For warranty repair, the steam generator must be returned to Saunacore with an Return Materials Authorization is to be obtained by the original consumer purchaser and must be shown on all correspondence and packaging, without this RMA # returns for repairs will NOT be accepted.

Table of Contents