Download Print this page
Saunacore Xtreme Steam Tech Steamcore Spa II User Manual

Saunacore Xtreme Steam Tech Steamcore Spa II User Manual

Advertisement

S T E A M G E N E R AT O R
S T E A M G E N E R AT O R
aobsessed with qualiy...
T M
aquality of life

Advertisement

loading
Need help?

Need help?

Do you have a question about the Xtreme Steam Tech Steamcore Spa II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Saunacore Xtreme Steam Tech Steamcore Spa II

  • Page 1 S T E A M G E N E R AT O R S T E A M G E N E R AT O R aobsessed with qualiy... aquality of life...
  • Page 2: Table Of Contents

    User Manual Manual Ä ¿ Â ¼ Users instruction----------------------------------------------------------------1 The steam equipment installation location----------------------------------- 1 The typical illustration of the steam equipment installation----------2 Installation of the steam line ---------------------------------------------- 3 Drawing of the steam generator----------------------- -----------------------5 Electrical requirements---------------------------------- ----------------------6 Power line assembly illustration------------ - ---------------------------------7 Generators internal electrical wiring---------------------------------------8 Installation of the mood light--------------------------------------------------11 Choosing your models-------------------------- ---------------------------------12...
  • Page 3: Users Instruction

    Prologue User Manual Certified to CAN/CSA Std. No. 88 Conforms to UL. Std. 499 Technical Hotline 905-951-6662 Ó Ã » § Ð ë Ö ª Users instruction We are not responsible for the malfunction and damage from Caution: installation that does not comply to the user manual. Î...
  • Page 4: Drawing Of The Steam Generator

    User Manual 7.Stable and horizontal.The steam generator has a hanging groove for mounting on the wall.Make sure the machine is steady and horizontally installed. 8.On both sides and the top of the steam generator needs at least 12 inches of clearance space. 9.The place where the machine is installed must be easily accesible and convenient for the disassembly of the machine.
  • Page 5 User Manual Installation of pipeline The installation of all the pipes should be done by a qualified Warning: licensed plumbe r. 1. Use threaded unions when connecting pipes to fill/drain valves and steam line(s). 2. Use brass or copper only. 3.
  • Page 6 User Manual Important: 1.Please consult your distributors of building materials like acrylic, fiber glass or other anti-heat sheet about the installation position of steam nozzle. It is suggested that MS- 103412 anti-heat material can be used. 2.In the entire steam room, it is required that steam must not leak out. The pipes, its accessories and the holes in the wall should be airproof by applying silicone so that no steam will enter the holes in the wall.
  • Page 7 User Manual Steam generator blue print. 395mm 130mm 304mm 35mm Steam outlet 209mm Safety valve Water inlet Water drainage Fuse for wire power supply C o n t r o l l e r w i r e Power wire hole and light wire hole (metal conduit connector required)
  • Page 8: Electrical Requirements

    User Manual 510mm 435mm 300mm 205mm Steam outlet Safety valve Water inlet Water drainage Fuse for wire power supply C o n t r o l l e r w i r e Power wire hole and light wire hole (metal conduit connector required) Fuse for wire...
  • Page 9 User Manual Ampere Meter The total connected load should not be more then 80% of the rating of the overcurrent devices. E l e c t r i c i t y E l e c t r i c Applicable space of Type supply...
  • Page 10 Wiring Diagram 240V(1PH) Steamcore Spa * * Supply Water Level Sensor To Control Panal Red(Short Pin) Terminal Block Black(Long Pin) Yellow(Middle Pin) Yellow/Green Black Black auto reset manual hi-limit reset Optional Blue hi-limit Black Light Brown Steamcore Spa * * 3kW (240V - 1PH) Supply Water Level Sensor To Control Panal...
  • Page 11 European Connection ( L2 = N "Neutral") Supply Water Level Sensor To Control Panal Red(Short Pin) Terminal Block Black(Long Pin) Yellow(Middle Pin) Yellow/Green Black Black auto reset manual reset hi-limit Optional Blue hi-limit Black Light Brown Steamcore Spa * * 10.5kW / 18kW (240V - 1PH)
  • Page 12 Wiring Diagram 208V (3PH) Steamcore Spa * * Supply Water Level Sensor To Control Panal Red(Short Pin) Terminal Block Black(Long Pin) Yellow(Middle Pin) Yellow/Green Black Black manual reset hi-limit Black auto reset Blue hi-limit Black Optional Light Brown 12 psi pressure switch (UL - USA Application 18kw & Up) Steamcore Spa * * 15kW / 18kW (208V - 3PH) Supply Water Level Sensor...
  • Page 13 User Manual Sizing steam generator Measure the length, width and height (feet) of the current steam shower or bathtub area that has a ceramic wall finish. Example; L:7xW:5xH:8 = 280 Cubic Feet x 25% for Ceramic Wall Finish = 61.25 (61.25+280) = 341 Total. You would need a 9000 watt (9KW) steam generator.
  • Page 14: Installation Of The Mood Light

    User Manual Installation of the top light CAUTION: The rating of the light should not surpass 40W(rated power) to prevent damage to the transformer. The light should be installed on the top of the steam room or in a place which is not access ible to children.
  • Page 15 User Manual Configuration of steam generator DO NOT HEAT DURING INSTALLATION. (heating with torch will cause damage to plastic solenoid valve) Subsidiary water tank Fuse Enclosure Circuit board Main water tank Fuse Steam Outlet Heating Element Ground wire connector Pressure Safety Valve Relay Heat Hi-limit Transformer...
  • Page 16 User Manual Controller Maintenance 1.Use soft cloth with a little soap/water to clean the controller . 2.Do not use harsh cleaning tools. 3.If the controller is damaged, call a service electrician to replace it. Safety and operation information of the controller Warning: If the installation and operation instruction is not read or understood, do not install.
  • Page 17: Control Panel (Both Ssi And Ssii) Dimensions

    User Manual Control panel (both SSI and SSII) dimension SSI and SSII Control panel may be switched for Spa II 160mm 70mm 23mm S S I 25mm 113mm 75mm S S I I Page 15...
  • Page 18 User Manual Installation instruction of controller Before installing the controller, make sure the steam generator is shut off Important: otherwise the controller may be damaged. Step one Determine the installation location of the controller. The controller is designed to be installed in the steam room : 1.
  • Page 19: Temperature Sensor Installation (Only For Ss I Control Panel)

    User Manual Step five Remove the paper on the b ackside . To achieve good sticking effect, keep the mounting surface clean and dry. Step six L o c a t e t h e d i s p l a y s c r e e n i n t h e Control Panel SS I Control Panel SS II direction of 12 o'clock, and press tight...
  • Page 20: Operation Instruction (Ss I Control Panel)

    User Manual Illustration of the controller panel (SS I Control Panel IN/OUT SHOWER USE LED SCREEN Power ON/OFF Steam Time Adjust Key--LOW Power Indicator LED Steam Temperature Adjust Key--LOW Steam Time Adjust Key--HIGH Steam Temperature Adjust Key--HIGH Mood Light Indicator LED Mood Light ON/OFF Steam ON/OFF Operation instruction (SS I...
  • Page 21 User Manual Mood Light When system is activated, press and release button to turn on the mood light. Indicator LED on the right of the button should be lit. Press and release button again to shut down mood light. Steam ON/OFF When unit is powered on, press and release button, water input steam boil tank automatically, press and release...
  • Page 22 User Manual Illustration of the controller panel (SSII & SQII) Control Panel IN SHOWER USE ONLY Power switch Time set button Time/temperature decrease button Time/temperature increase button Light function button Temperature set button Digital display screen Steamcore The front decorative panel Temperature sensor Operation instruction (SSII &...
  • Page 23 User Manual When the actual temperature is smaller than or equal to 32 , the digital tube will display 32 . When the actual temperature is smaller than or equal to 110 F , the digital tube will display . The last digit displays as the unit of Fahrenheit 110 F temperature.
  • Page 24: Maintenance Of The Steam Generator

    User Manual Light function When the machine is started, press button repeatedly to turn on/off light function. When the light is turned on, the digital tube will temporarily display (as is shown in Fig.6). When the light is turned off, the digital tube will temporarily display (as is shown in Fig.7).
  • Page 25 S t e a mc o r e I n t e l l i S t e a m O p e r a t i n g I n s t r u c t i o n s Congratulations on your new Saunacore steam unit with the advanced IntelliSteam controller! This booklet will help you get the most enjoyment out of your device’s many capabilities and features.
  • Page 26 NOTE 1: controller keys are touch-sensitive, and do not require physical pressure. NOTE 2: The power button, located on the upper front of the unit, performs several different functions, depending if it’s touched momentarily, or “held” for several seconds. It also is an LED indicator which glows: RED- System in standby mode GREEN- (Display indicator flashing) Keypad is locked, keys are disabled.
  • Page 27 5.Ozoner (opt) With the system on, touch the O3 key to initialize the ozone function (if unit so equipped). To turn off, touch the O3 key again. 6.Fan (opt) With the system on, touch the Fan key to turn it on. The display will indicate fan operation. 7.Light (opt) The Light key will operate the lights in several ways, as follows: With the system on, touching the Light key once turns on the background light (display shows L1).
  • Page 28 10. MP3 Feature Turn on the system, and plug your flash drive into the provided USB slot. Touch the USB key, and your music will play automatically. The screen will display the current music title, remaining time, etc. Press the Up key to jump to the next track (s), or the Down key for the previous track(s).
  • Page 29 This set of instruction pages is to be used in combination with the Steamcore Steam Bath installation manual provided with each steam bath generator.
  • Page 30 ight Page 28...
  • Page 32 User Manual Common trouble shooting methods To facilitate your use and maintenance of sauna room, the following common trouble shooting methods are listed for reference. Causes of troubles Trouble-shooting methods Troubles 1.The fuse is burned. 1.Change the fuse (on the shell 0.8A/ 2.The wire connection terminal The machine 250V)
  • Page 33 User Manual Important: Consult a licensed electrician for service. Technical parameter TYPE Steamcore Spa II 240V 240V 240V 240V 240V 208V 240V 240V 208V 208V 208V 208V (1PH) (1PH) (1PH) (1PH) (1PH) (3PH) (1PH) (1PH) (3PH) (3PH) (3PH) (3PH) Current(A) 12.5A 18.75A 31.25A 37.5A 25A x 3...
  • Page 34 Warranty applies only to the original consumer purchaser, warranty is non-transferable. For warranty repair, the steam generator must be returned to Saunacore with an Return materials Authorization # and is to be obtained by the original consumer purchaser and must be shown on all correspondence and packing, without this RMA # returns for repairs will NOT be accepted.