Toshiba Q9 Plus Bypass ASD Installation & Operation Manual page 305

Hide thumbs Also See for Q9 Plus Bypass ASD:
Table of Contents

Advertisement

Title
Panel emergency stop operation
f734
prohibition
f735 Panel reset operation prohibition
cmod / fmod change prohibition
f736
during operation
All key operation prohibition

f738 Password setting (f700)
f739 Password verification
Parameters can be edited regardless of the setting of f700 by assigning the parameter editing
permission (function number 110, 111) to an input terminal.
Note1: f700=2 and 4 will be available after reset operation.
When protection using a password is necessary, set and remove with the following method.
■ Password setup method
Preparation: Parameters other than f700, f738, and f739 cannot be changed when f700 is set
to 1 to 4.
(1)
When f738 or f739 is read out and the value is 0, a password hasn't been set.
You can set a password.
(2)
When f738 or f739 is read out and the value is 9999, a password has already been set.
(3)
You can set a password If it hasn't been set. Select and register a number from 1 to 9998 for f738.
The number is the password. Do not forget your password as it is required to release the lock.
(4)
The settings for parameter f700 cannot be changed.
Note2: The lock cannot be released If you forget the password. Do not forget this password as we cannot
retrieve it.
Note3: Password cannot be set when parameter f700=0.
Set the password after parameter f700=1 to 4.
Note4: Password can be read out to parameter writer (optional device) only for 5 minutes after setting
. Please note that password will not be able to read out due to password protection after 5
minutes have elapsed or when the power is off.
■ Password examination method
(1)
When f738 or f739 are read out and the value is 9999, a password has already been set.
Password has to be removed in order to change parameters.
(2)
Enter a the number (1 to 9998) registered to f739 when the password was set for f738.
(3)
If the password matches, pass blinks on the display and the password is removed.
(4)
If the password is incorrect, fail blinks on the display and f739 is displayed again.
(5)
When the password is removed, the setting for parameter f700 can be changed.
(6)
By setting parameter f700=0, the all parameter settings can be changed.
Note5: Entry of  setting is possible up to 3 times. Please note it is impossible to set, if you enter the
wrong number for 3 times. Number of times is reset after power is off.
Function
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Permitted, 1: Prohibited
0: Password unset
1-9998
9999: Password set
0: Password unset
1-9998
9999: Password set
F-125
Adjustment range
Default setting
E6581611
0
0
1
0
0
0
6

Advertisement

Table of Contents
loading

Table of Contents