Page 2
Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your Concept Design 384: this information will assist us in providing spare parts, repairs or in an- swering any technical enquiries with the utmost speed and accuracy.
Congratulations on having purchased a Coemar product. You have assured yourself of a fixture of the highest quality, both in componentry and in the technology used. We renew our invitation to you to complete the service information on the previous page, to expedite any request for service information or spares (in case of problems encountered either during, or subsequent to, installation).
3. The level of technology of Concept Design 384 requires the use of specialised personnel for all service applications; refer all work to your authorised Coemar service centre. 4. A good earth connection is essential for the proper functioning of the fixture. Never con- nect the fixture if there is no earth connection.
Product specifications Technical characteristics Power supply 90-260 V, auto-sensing, 50/60 Hz Maximum current 3 A @ 230 V, 5 A @ 115 V Power factor Cosφ = 0.9 Max power consumption 500 W - 350 mA Maximum internal temperature 80 °C / 176 °F Maximum external temperature 35 °C / 95 °F Weight (without optic)
Installation Mechanical installation Concept Design 384 can be placed on a shelf or inserted in a standard rack by the two mounting brackets enclosed. 484 mm 19.05 in 462 mm 118.19 in Powering up Operating voltage and frequency The fixture may operate at voltages from 90 to 260 V at a frequency of 50 or 60 Hz. It is not necessary to effect any setup procedures, Concept Design 384 will automatically adjust its operation to suit any frequency or voltage within this range.
Connections LEDs connection Concept Design 384 can at the same time supply up to 8 outputs, each output can control up to 4 channels at 350 mA constant current and a maximum of 47 Volts. LEDs connection must be done...
DMX mode Mast DMX connection Concept Design 384 can work in DMX mode and it can be controlled by a DMX controller: DMX controller Master Slave Slave Slave 57 7 Other units Signal connection via XLR5 connectors: Connection is to international standards. Connection is as indicated below.
Turning the fixture on and DMX functions Turning the unit on After Concept Design 384 has been connected to mains, to the controller and to the LEDs, the unit will turn on automatically. The display will turn on showing the actual DMX channel (A001 default setting). If the DMX signal is not con- nected the address will blink.
DMX Chart 64 channels type zones channel function effect decimal percentage of control master dimmer proportional control of the percentage of light channel proportional - 255 - 100% ch 1.1 from 0 to 100% master fine proportional fine dimmer control 16 bit - 255 - 100% dimmer ch 1.1...
Page 13
master dimmer proportional control of the percentage of light channel proportional - 255 - 100% ch 5.1 from 0 to 100% master fine proportional fine dimmer control 16 bit - 255 - 100% dimmer ch 5.1 master dimmer proportional control of the percentage of light channel proportional - 255 - 100%...
DMX Chart 48 channels type zones channel function effect decimal percentage of control master proportional adjust luminous output intensity from 0 to 100% - 255 - 100% dimmer out 1 master fine proportional fine dimmer control 16 bit - 255 - 100% dimmer out 1 proportional control of the percentage of light channel...
Page 15
master proportional adjust luminous output intensity from 0 to 100% - 255 - 100% dimmer out 5 master fine proportional fine dimmer control 16 bit - 255 - 100% dimmer out 5 proportional control of the percentage of light channel dimmer ch 5.1 proportional - 255...
DMX Chart 32 channels type zones channel function effect decimal percentage of control proportional control of the percentage of light channel dimmer ch 1.1 proportional - 255 - 100% from 0 to 100% proportional control of the percentage of light channel dimmer ch 1.2 proportional - 255...
DMX Chart 6 channels type zones channel function effect decimal percentage of control master proportional adjust luminous output intensity from 0 to 100% - 255 - 100% dimmer master fine proportional fine dimmer control 16 bit - 255 - 100% dimmer proportional control of the percentage of light channel dimmer ch 1...
ENTER button to access to any other function. By suitably using all the functions of Concept Design 384, which can be activated through its display panel, it is possible to change some of the parameters and to add some functions. Changing the preset settings made by Coemar can vary the functions of the fixture so that it will respond differently to the controller;...
Main functions menu (FUNC) Dimmer: It allows to choose the type of dimmer curves between exponential, logarithmic and linear dIMM (exponential as default). [Exponential] Test: Allows to set manually some different options: • Dimmer: it allows to set the luminous inten- [Logarithmic] sity;...
Page 20
DMX channels: Allows to choose the DMX mode in which the fixture must operate. 64 CH Default Settings: [64 channels] Allows to restore the factory default of the fix- [DMX channels] ture, with exception of DMX address. 48 CH [48 channels] Measures: Allows to read all the parameters: board tem- 32 CH...
Measures menu (MEAS) DMX Input: dM.In. Shows the value of the DMX channels received CH 1 by the fixture on every channel that the fixture [Channel 1] occupies on the line. [DMX Input] CH 2 DMX rate: [Channel 2] Shows the refresh rate of the DMX signal sent by the console.
To decrease the noise and the power consumption, the cooling fan turns off after 10 minutes of fixture inactivity. Error messages If a malfunction occurs, Concept Design 384 has a self-diagnostic system that will show the error message on the display. The following table will explain in detail the most common errors. If, despite of suggested interven- tion, the problem persists, call the Coemar Service Center.
Accessories and spare parts All the components of Concept Design 384 are available as spare parts from your Coemar service center. Accu- rate description of the fixture, serial number and type will assist us in providing for your requirements in an efficient and effective manner.
F.A.Q. and answers The following list shows common issues that may be simply solved. If issues persist, the unit must be repaired by qualified personnel or just contact your Coemar service near you. Question Possible solution Concept Design 384 does not...
Page 25
User notes ......................................................................................................................................................................................................................................................................................................................................................................................................................................................
Page 26
Information on disposal of the equipment The equipment at the end of its useful life must be disposed of at an appropriate recycling center for waste electrical and electronic equipment. The treatment and disposal of environmentally friendly, helps prevent potential negative environ- mental and health and promote the reuse and / or recycling of materials making up the equipment.
Page 27
Coemar Lighting s.r.l. Via Carpenedolo 90 46043 Castiglione delle Stiviere, Mantova, Italy phone. +39 0376/1514412 - fax +39 0376/1514380 info@coemar.com Coemar reserves the right to change specifications without prior notice...
Need help?
Do you have a question about the Concept Design 384 and is the answer not in the manual?
Questions and answers