Ho 2 DIGIFACTOR a 6 canali e uno ogni 2 secondi mi spegne tutti i fari per 2 secondi e lo ripete continuamente ogni 5 minuti circa .
Mi da errore , ma non ricordo quale
Chi lo può riparare ?
1 comments:
Mr. Anderson
May 28, 2025
The error could be caused by a defective or missing EEPROM in the DIGIfactor 6x2.5Kw unit, forcing it to operate only at factory presets and ignoring changes made via the menu functions. This may lead to issues such as the lights turning off every 5 minutes. The EEPROM may also be reinitializing repeatedly due to being erased or new. Only a Coemar service centre can repair this issue.
This answer is automatically generated
Subscribe to Our Youtube Channel
Related Manuals for Coemar DIGIfactor club 6x2,5Kw
Summary of Contents for Coemar DIGIfactor club 6x2,5Kw
Page 1
Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your DIGIfactor club 6x2,5Kw : This information will assist us in providing spare parts, repairs or in answering any technical enquiries with the utmost speed and accuracy.
Page 2
9.1.1. Testing individual channels 9.2 Electrical and electronic displays 9.2.1. Voltage 9.2.2. Frequency 9.2.3. Temperature 9.2.4. DIGIfactor club 6x2,5Kw hours of operation 9.2.5. DMX 512 parameter displays 9.2.6. Individual channel DMX 512 input signal levels 9.2.7. Individual channel input signal levels 0/+10V DC 9.2.8.
2. Technical characteristics DIGIfactor club 6x2,5Kw is a dimmer rack allowing control over the output of 6 channels from 0 to 230V. The six chan- nels may be loaded to a maximum of 2,5KW; therefore resulting in a maximum current of 10 Amps per channel.
Load voltage regulation is via internally mounted Triacs; these components will heat up when a load is connected; the DIGIfactor club 6x2,5Kw needs to disappate this heat and for this reason the unit needs to be located in a well-ventila- ted position, leaving a minimum of 2 centimetres clearance around the unit housing and any adjoining surfaces.
4. Connection to mains power DIGIfactor club 6x2,5Kw is a dimmer rack suitable for power supply via 3 phase 230V. 230V single phase supply is possible, but will not allow the unit to be used in adherance to certain safety norms concerning electrical operation and electromagnetic radiation emission.
Page 6
For proper powering up of the DIGIfactor club 6x2,5Kw we recommend the use of a termal/magnetic circuit breaker of sufficient rating, as indicated in the diagram. Attention DIGIfactor club 6x2,5Kw is a high-technology dimmer running on mains power; only qualified personal should perform installation, after thorough examination of this manual, and bearing in mind all local norms.
A good and secure earth connection is essential. 1) Loosen the four screw (A) on the rear panel (B) of the DIGIfactor club 6x2,5Kw; using a cable of suitable rating slide it through the cable clamp (C) located on the rear of the unit and secure it firmly.
6.1 DMX 512 DIGIfactor club 6x2,5Kw receives, via an XLR 5 plug, 6 channels of DMX 512 digitally addressed as 1 to 6; using the signals to to control the output levels of 6 channels in the range of 0 to 255, as per the DMX 512 standard, regulated by USITT (U.S Intitute of Theatre Technology)
Page 9
Screening should alwasy be connected to pin 8 of the locking-din. Shown is a typical 0/+10v DC connection between controller and DIGIfactor club 6x2,5Kw. pin1: gnd...
Page 10
DIGIfactor club 6x2,5Kw will also display the voltage above 250V or below 180V. When the display shows A001(or any other value preceded by the letter A), the DIGIfactor club 6x2,5Kw is ready for normal operation.
Page 11
8. DMX addressing or analogue 0/+10v DC As described in section 6 you may use the DIGIfactor club 6x2,5Kw with either 0/+10V DC or DMX 512 control signals; depending upon the requirements of your controller 8.1 0/10 v DC After having correctly connected the cable, channel number 1 of the DIGIfactor club 6x2,5Kw corresponds to the signal being sent via pin 1 of the Locking DIN;...
Page 12
Altering the coemar factory presents can vary the functioning of the dimmer, causing it to not respond to DMX 512 con- trol signal; careful and thorough reading of all the following procedures is therefore recommended prior to altering any functions.
Press the enter button To confirm your selection Press the + or - buttons voltage displayed function display DIGIfactor club 6x2,5Kw measures the volta- Press the enter button ge across one phase, for example phase1 voltage function display is 230v 9.2.2.
Page 14
In such an instance, the addition of a further fan at the base of the unit, may be appropriate. 9.2.4. DIGIfactor club 6x2,5Kw hours of operation Displays the number of hours that the DIGIfactor club 6x2,5Kw has been operated (in hours) Power up DIGIfactor club 6x2,5Kw...
Page 15
Press the + or - button DIGIfactor club 6x2,5Kw receives a new packet of signal (DMX) DIGIfactor club 6x2,5Kw displays the value in Press the enter button Hertz function display Recommended values: Minimum 1, maximum 44 Hz.
Page 16
Press the + or - button to select the next channel For example, channel number 6 you wish to display function display DIGIfactor club 6x2,5Kw will display the inco- Press the enter button ming 0/+10v signal level of the selected channel, function display for example a level of 8 volts 9.2.8.
Page 17
(in volts). function display For example, 230 volts. 9.3. Advanced functions (installer options) ATTENTION! Modifying these settings will modify the operation of the DIGIfactor club 6x2,5Kw. Use these functions only when necessary. 9.3.1. Lamp pre-heating Power up DIGIfactor club 6x2,5Kw...
Page 18
Sets a maximum output voltage (between the maximum output voltage and 180V) which the selected channel can achieve. Suitable if the dimmer is located close to the generator or sub-station by preventing lamp failure due to over-voltage supply. Power up DIGIfactor club 6x2,5Kw DIGIfactor club 6x2,5Kw turns on...
Page 19
ScH1 as described above. Power up DIGIfactor club 6x2,5Kw DIGIfactor club 6x2,5Kw turns on Simultaneously press the menu and enter but-...
Page 20
DIGIfactor club 6x2,5Kw sets the dimmer Press the + or - button until the required output channel(s) to the set minimum level, regardless of voltage is achieved function display incoming DMX signal Press the enter button To record the level in memory 9.3.5.
Page 21
Press the + or - buttons until the number of the For example, number 3 required memory is displayed function display DIGIfactor club 6x2,5Kw reads the incoming Press the enter button signal, 0/+10V or DMX 512.The display will function display flash to indicate that the recording is unconfirmed.
9.3.8. Protection against over-heating You may select the type of action which DIGIfactor club 6x2,5Kw will effect in case it begins to overheat. off: no protection Pr 1: if the internal temperature exceeds 75 °C any channels previously set as dimming will lower their maximum output by up to 50% upon reaching 85 °C.
Page 23
To confirm your selection function display From this point DIGIfactor club 6x2,5Kw will output the levels as previously recorded and the address display will include a decimal point, indicating a pre-recorded scene is currently being outputted. Indication that a pre-recorded scene is currently...
Page 24
To confirm your selection function display From this point DIGIfactor club 6x2,5Kw ceases to output the levels of the pre-recorded scene. Note that the address display no longer has a decimal point present Note the decimal point between the A and the...
Page 26
10.Remote back-up scene restoration DIGIfactor club 6x2,5Kw allows a remote signal to be used to restore a back-up scene. This may be useful in case a pro- blem occurs with the controller normally used with the dimmer. The scene should be recorded as described in section 9.3.7 and may be activated as described below.
11. Error messages DIGIfactor club 6x2,5Kw assists the installer and user in determining the reasons for possible failures; its memory contains the following error messages. In the majority of cases, it may be advisable to seek the advice of an individual who has experience with the causes of errors which are described below The internal temperature has exceeded 65°.
Page 28
The EEPROM is being re-initialised. This may occur if the EEPROM is new or has been erased comple- tely. It is being re-initialised with the unit’s default settings. function display...
7) Follwing this. re-test the unit as described in section 9.1.1. If, after this point, the dimmer is still not generating the required output, refer the unit to your authorised coemar service centre for assistance with your DIGIfactor club 6x2,5Kw.
Page 30
3) Test the unit is functioning correctly and replace all components and covers. Periodic cleaning The fan and air passages should be inspected and cleaned at least every 12 weeks; this period of time may be shorter depending upon the unit’s operating conditions. To effect this cleaning use a common brush, vacuum cleaner, or air compressor.
13.Spare parts All the components of the DIGIfactor club 6x2,5Kw are available as spare parts from your authorised coemar service centre. To assist us in providing your with prompt and accurate service, carefully specify the model and serial number of the unit, and the spare parts which you require.
Need help?
Do you have a question about the DIGIfactor club 6x2,5Kw and is the answer not in the manual?
Questions and answers
Ho 2 DIGIFACTOR a 6 canali e uno ogni 2 secondi mi spegne tutti i fari per 2 secondi e lo ripete continuamente ogni 5 minuti circa . Mi da errore , ma non ricordo quale Chi lo può riparare ?
The error could be caused by a defective or missing EEPROM in the DIGIfactor 6x2.5Kw unit, forcing it to operate only at factory presets and ignoring changes made via the menu functions. This may lead to issues such as the lights turning off every 5 minutes. The EEPROM may also be reinitializing repeatedly due to being erased or new. Only a Coemar service centre can repair this issue.
This answer is automatically generated