Sharp IM-DR580H(S) Service Manual page 56

Table of Contents

Advertisement

IM-DR580H
IC201 VHiLR37820+-1 : Endec/Servo/Atrac (LR37820) (3/3)
Terminal Name
Pin No.
104
DGND
105*
SBCK
106*
SBO
107*
SBSY
108*
SFSY
109
VDD5
110
FOK
111
SENSE
112
COUT
113
MCCK
114
DINTX
115
VDD1
116
DGND
117
RSTX
118
SYD0
119-124 SYD1-SYD6
125
SYD7
126
SYWRX
127
SYRDX
128
SYRS
In this unit, the terminal with asterisk mark (*) is open terminal which is not connected to the outside.
List of TEST port settings
TEST1
TEST0
H
H
H
L
L
H
L
L
Input/Output
Schmidt Input/
Three-state Output
Output
Output
Output
Input
Output
Output
Output
Output
Output
Input
Schmidt Input
Schmidt Input/
Three-state Output
Schmidt Input/
Three-state Output
Schmidt Input/
Three-state Output
Schmidt Input
Schmidt Input
Schmidt Input
Details
Normal mode
No adjustment mode
Test mode
(Settings prohibited)
Digital GND.
DIN subcode read clock. Expansion port 3.
DIN subcode serial data. Expansion port 2.
DIN subcode block sync signal. Expansion port 0.
DIN subcode frame sync signal. Expansion port 1.
Power supply for interface.
Focus OK detection signal.
Servo status detection signal.
Track cross signal output.
Clock output for microcomputer.
Terminal of interrupt request output to system control interface.
Power supply for interface.
Digital GND.
Chip reset input. L: reset. (Note)
Data bus terminal of system control interface. (LSB)
Data bus terminal of system control interface.
Data bus terminal of system control interface. (MSB)
Register write pulse input of system control interface.
Register read pulse input of system control interface.
Register selection input of system control interface.
List of LDCNT port settings
LDCNT1
H
H
L
L
– 56 –
Function
LDCNT0
Details
H
Brake
L
Drive UP
H
Drive DOWN
L
Output OFF

Advertisement