5. MAINTENANCE

5.1. Cleaning and maintenance

All maintenance services need to be performed after disconnecting the device from power supply!
Protect electric installation against any damage or water spillage
Do not use water stream to clean the device, only a wet cloth
Do not use any sharp objects to remove filth!
First cleaning of the device should be performed after unpacking and before actuating the device. The device should
be cleaned with water and neutral cleaning agents. Do not use surface scratching agents, caustic agents or agents
containing chlorine and/or soda. Possible glue or silicone residues on metal elements should be removed solely with
extraction naphtha (does not concern elements made of plastic!). Do not use other organic solvents.
Podczas eksploatacji witryny jak również podczas prac konserwatorskich należy uważać, aby nie uszkodzić
czujki temperatury znajdującej się w przysłonce parownika!
It is recommended to make a break in the exploitation of the device once a month in order to clean its interior, naturally
defrost the evaporator, clean the condenser and verify the condition of door seals.
Do not use mechanical agents in order to fasten the defrosting process!
Rys.12 Czyszczenie skraplacza
It is essential to keep the condenser of the device cle-
an. Dirt may hinder the heat exchange, causing mainly
increase in electric energy consumption and may cause
damage of aggregate compressor.
In order to clean the condenser it is necessary to
unscrew the sheet metal screws and pull the wind bra-
ce out Fig.8/1 (p.12). Clean condenser lamellas Fig.8/2
(p.12) with help of soft brush or paintbrush. If the con-
denser is extremely dirty (blocked lamellas) it is indica-
ted to use vacuum cleaner or compressed nitrogen to
suck / blow the dirt from between lamellas.
The producer shall not be held responsible for damages of the condenser aggregate resulting from non-
observance of condenser cleanliness!
8
16
User manual Basia 2, Tobi
1
2
4
5
2
6
7

Fig.9 Changing the fluorescent lamp

3
1 – Night roller
2 – Fluorescent lamp
3 – Upper shelf (cover)
4 – Starting switch of the fluorescent lamp
5 - Casing of fluorescent lamp and starting switch
6 – Base profile (PVC)
7 – Fluorescent lamp handle
8 – Transparent casing of fluorescent lamp
During maintenance services it is necessary to
pay attention not to damage the data place of
the device Fig.10 (p.17), which contains signifi-
cant information for servicing organs and waste
removal companies.