Service And Maintenance - Mitsubishi Electric EHGT17D-YM9ED Service Manual

Table of Contents

Advertisement

12

SERVICE AND MAINTENANCE

Engineers Forms
Commissioning/Field settings record sheet (continued from the previous page)
Main remote controller screen
Setting
Service
Thermistor
menu
adjustment
Auxiliary settings
Pump speed
Heat source setting
Heat pump settings
Operation
settings
OCH722A
Parameters
THW1
−10°C to +10°C
THW2
−10°C to +10°C
THW5A
−10°C to +10°C
THW5B
−10°C to +10°C
THW6
−10°C to +10°C
THW7
−10°C to +10°C
THW8
−10°C to +10°C
THW9
−10°C to +10°C
THW10
−10°C to +10°C
THWB1
−10°C to +10°C
Economy settings for
On/Off *2
pump.
Delay (3 to 60 min)
Electric heater
Space heating: On (used)/Off (not used)
(Heating)
Electric heater delay timer (5 to 180 min)
Electric heater
Booster heater
(DHW)
Immersion heater
Electric heater delay timer (15 to 30 min)
Mixing valve
Running (10 to 240 sec)
control
Interval (1 to 30 min)
Flow sensor *10
Minimum (0 to 100L/min)
Maximum (0 to 100L/min)
Analog output
Interval (1 to 30 min)
Priority (Normal/High)
DHW
Pump speed (1 to 5)
Heating
Pump speed (1 to 5)
Standard/Heater/Boiler/Hybrid *3
Heat pump flow rate
Minimum (0 to 100L/min)
range
Maximum (0 to 100L/min)
Quiet mode
Day (Mon to Sun)
Time
Quiet level (Normal/Level1/Level2)
Heating
Flow temp.range
Minimum.temp. (20 to 45°C)
operation
*6
Maximum.temp. (35 to 60°C)
*4
Room temp.
Mode (Normal/Fast)
control
Interval(10 to 60min)
*9
Heat pump
On/Off *2
thermo diff.adjust
Lower limit (−9 to −1°C)
Upper limit (+3 to +5°C)
Freeze stat function *7
Outdoor ambient temp. (3 to 20°C) / **
Simultaneous operation (DHW/
On/Off *2
Heating)
Outdoor ambient temp. (−30 to +10°C)
Cold weather function
On/Off *2
Outdoor ambient temp. (−30 to −10°C)
Boiler operation
Hybrid settings
Intelligent set-
tings
DHW: On (used)/Off (not used)
DHW: On (used)/Off (not used)
Outdoor ambient temp. (−30 to +10°C)
Priority mode (Ambient/Cost/CO 2 )
Energy
Electricity (0.001 to 999 */kWh)
price *5
Boiler (0.001 to 999 */kWh)
CO 2
Electricity
emission
(0.001 to 999 kg -CO2/kWh)
Boiler
(0.001 to 999 kg -CO2/kWh)
Heat
Heat pump capacity (1 to 40 kW) 11.2 kW
source
Boiler efficiency (25 to 150%)
Booster heater 1 capacity
(0 to 30 kW)
Booster heater 2 capacity
(0 to 30 kW)
94
Default
Field
Notes
setting
setting
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
0°C
On
10 min
On
30 min
On
On
15 min
120 sec
2 min
5 L/min
100 L/min
5 min
Normal
5
5
Standard
5 L/min
100 L/min
0:00-23:45
Normal
30°C
50°C
Normal
10min
On
-5°C
5°C
5°C
Off
−15°C
Off
−15°C
−15°C
Ambient
0.5 */kWh
0.5 */kWh
0.5 kg -CO2/kWh
0.5 kg -CO2/kWh
80%
2 kW
4 kW
(Continued to next page.)