  • Page 1 Intense (THY & THYW) Product Manual HEATSTRIP® Intense & Intense White (THY & THYW) www.heatstrip.com.au Ph: 03 9562 3455 E: sales@thermofilm.com.au...
  • Page 2 – similar to the heat rays emitted by the Sun. Radiant heating is the only viable option for outdoor or tough indoor sites. Maximum heat performance – multiple applications ® The high temperature output of the HEATSTRIP Intense is perfect for exposed outdoor sites, high ceilings and hard-to-heat indoor and outdoor applications.
  • Page 3 Specifications - Australia LEAD POWER CURRENT DIMENSIONS WEIGHT MODEL LENGTH PLUG COLOUR (WATTS) (AMPS) (mm) (Kg) (mm) THY2200 2200 1068 x 120 x 90 1000 Black THY3200 3200 13.3 1270 x 120 x 90 1000 Black THY2200W 2200 1068 x 120 x 90 1000 Off-White THY3200W...
  • Page 4 ® The top diagram shows how HEATSTRIP Intense is recommended to be used directly over a table, while the bottom diagram indicates how to spot heat a large area.
  • Page 5: Selection Guide

    • Ideal mounting location: ceiling mounted, directly above area to be heated (e.g. above a table) ® The below table outlines the coverage HEATSTRIP Intense model (in m ), based on 3 different scenarios. For example, in an outdoor area that is protected from prevailing winds by walls, café blinds etc, (e.g. outdoor enclosed) This data is based on direct overhead ceiling mounting.
  • Page 6 Selection are based on HEATSTRIP Intense being mounted at 2.4m from the floor in a fully enclosed undercover outdoor area.
  • Page 7: Installation Requirements

    For mounting heights more than 2.8m outdoors, we recommend the use of the optional accessories to reduce the height of ® the heater to 2.3m—2.5m. This will increase the effectiveness of your HEATSTRIP . Refer to the Mounting Accessory section for more information.
  • Page 8: Installation Location

    Installation location — the below diagrams confirm the minimum recommended clearances. Angled Wall Installation Surface Below Lights, fans, and sprinklers Heater must NOT be below heater Ceiling Installation 1000 min. Surface Below Lights, fans, and sprinklers Heater must NOT be below heater Angled Ceiling Installation...
  • Page 9: Mounting Options

    Mounting options ® The installation of HEATSTRIP Intense is simple and easy with the standard mounting brackets supplied. For other more challenging locations there are a range of mounting options available - refer to below diagrams. ® The HEATSTRIP Intense can be mounted directly to the ceiling, flush mounted into the ceiling, angled downwards on a wall, suspended on chains, poles or attached to beams and rafters.
  • Page 10: Standard Mounting Brackets

    Standard mounting brackets ® The HEATSTRIP Intense comes with a pair of standard mounting brackets. These adjustable brackets allow direct ceiling or wall mount, and come with pre-set angle options of parallel, 22.5° and 45°. The flexible standard mounting bracket can be turned 90 degrees to mount onto a beam, it can also be used to suspend with chains.
  • Page 11 MOUNTING Fix the two mounting brackets to the ceiling or wall in the desired location (refer minimum bracket centre chart). Make sure the method of fixing (bolts or screws) will be more than strong enough to support the weight of the heater, allowing for strong winds and other conditions.
  • Page 12 Extension Mount Bracket ® The Extension Mount bracket allows HEATSTRIP Intense units to be lowered from high ceilings using rigid connections. The standard length options as part of the kit are 300mm, 600mm, 900mm and 1200mm. The extension mount bracket utilises components from the standard bracket kit which is supplied with each heater.
  • Page 13: Flush Mount Enclosure

    Flush mount enclosure ® The Flush Mount Enclosure is an ideal way to neatly install the HEATSTRIP into a ceiling. They are available for the ® HEATSTRIP Intense model, and are supplied as a one-piece unit suitable for mounting individual heaters. Flush mounting can be used with plaster or timber lined ceiling materials.
  • Page 14 The TT-MTR-PLUG has been designed to provide easy remote control timer functionality to wall socket powered HEATSTRIP heaters. The unit can however be used to remotely operate with timer functionality any device powered by a standard 10A Australian wall socket outlet.
  • Page 15 Wall Controller with Remote TT-MTM2 Wall Controller This controller is a custom designed and manufactured controller for HEATSTRIP heaters. It has been designed for ease of use and to provide low running costs of your heater. It provides both temperature control (allowing the user to turn the heat output up or down depending on the ambient temperature and conditions) and a timer for automatic heater shut-off operation.
  • Page 16 Operation Press “On/Off” button to turn power on and off. Once turned on, the controller will default to High power setting and will be permanently on (no timer function). Press “POWER” button to select the desired power setting by cycling through HIGH—MEDIUM-LOW.
  • Page 17 TT-MTM2 Controller Installation Guide The TT-MTM2 Controller required sufficient air circulation in order to provide continuous operation on the high power load setting. The vents must always remain clear; never block or cover the vents. An ideal controller installation will provide significant space around the back of the controller. In- stalling into restricted spaces, such as brick walls, may result in overheating if adequate ventilation is not provided.
  • Page 18 Heater wiring schematic diagrams It is recommended to install an ON/OFF isolation switch before the controller and ensure the unit is turned OFF after use. Multiple heaters can be operated using a single controller, however the maximum current rating of 16A must not exceeded.
  • Page 19: Maintenance

    Safety ® ® HEATSTRIP Intense has an IP rating of X5. This means it is safe for water ingress from all directions. The HEATSTRIP can be safely hosed down. ® HEATSTRIP has undergone extensive testing both in laboratory conditions; in Thermofilm’s assembly facility in Melbourne and field trials in Australia and overseas.
  • Page 20: Warranty Terms And Conditions

    ® Thermofilm warrants to the original owner that HEATSTRIP Intense products will be free from defects in materials and workmanship for a period of 24 months for residential applications (and 12 months for commercial applications) from the date of purchase in accordance with the following warranty terms and conditions.