NEFF S185HCX01A User Manual page 44

Hide thumbs Also See for S185HCX01A:
Table of Contents

Advertisement

aus Troubleshooting
Fault
Appliance door does
not open.
Appliance door opens
too wide when activ-
ated.
Fault
E:20-60 lights up al-
ternately.
E:30-00 will light up
alternately.
E:31-00 will light up
alternately.
E:32-00 will light up
alternately or indicator
for water supply lights
up.
1
Depending on the appliance specifications
44
Cause and troubleshooting
Automatic door opening is not in home position.
Wait one second after closing the appliance door.
Door is not correctly adjusted.
Adjust the appliance door as described in the in-
stallation instructions.
Cause and troubleshooting
Appliance has detected calcified heating element.
Descale the appliance.
1.
Operate the appliance with the water softening
2.
1
system.
Water protection system is activated.
Turn off the water tap.
1.
Call Customer Service → Page 57.
2.
Water protection system is activated.
Turn off the water tap.
1.
Call Customer Service → Page 57.
2.
Supply hose is kinked.
Install the supply hose without kinks.
Water tap is turned off.
Turn on the water tap.
Water tap is jammed or furred up.
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
The filters in the water connection of the supply or
AquaStop hose are blocked.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.

Advertisement