EDWARDS SYSTEMS TECHNOLOGY EST3 Manual
Hide thumbs Also See for EST3:

Advertisement

Quick Links

EST3
International Installation
Supplement Manual
P/N 270925 • Rev 1.0 • 24JAN00
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com

Advertisement

Table of Contents
loading

Summary of Contents for EDWARDS SYSTEMS TECHNOLOGY EST3

  • Page 1 EST3 International Installation Supplement Manual P/N 270925 • Rev 1.0 • 24JAN00 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 2 Copyright © 2000. All rights reserved. COPYRIGHT NOTICE This manual and the products it describes are copyrighted by Edwards Systems Technology, Inc. (EST), and others under separate licensing agreements. You may not reproduce, translate, transcribe, or transmit any part of this manual without express, written permission from EST.
  • Page 3 Content Important information • ii About this manual • iii The EST3 library • iv Related documentation • iv Chapter 1 European Marketplace: Installation • 1.1 General system requirements and special considerations • 1.2 LPCB/EN-54-compliant systems • 1.2 CE-compliant systems • 1.8 Installing E series cabinets •...
  • Page 4 While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, EST assumes no responsibility for errors or omissions. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 5 This manual only contains information specific to systems installed outside the United States and Canada. It is intended to supplement the EST3 Installation and Service Manual, which should be the primary source of information. Chapter 1 provides special procedures for the installation and electrical wiring of system components as required for LPCB approval/certification.
  • Page 6 Content The EST3 library A family of documents and multi-media presentations supports the EST3 network. A brief description of each document is provided below. EST3 Installation Manual and Service Manual, P/N 270380. This manual provides complete information on how to install and service the EST3 hardware.
  • Page 7 9/31/EEC Directive EN50130-4; 1995 Immunity Requirements for Components of Fire, Intruder, and Social Alarm Systems EN55022:1995 Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 8 Content EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 9: Table Of Contents

    Installing the 3-ASU/FT Audio Source Unit with Firefighter's Telephone • 1.20 Assembling the 3-ASU/FT • 1.20 Wiring the 3-ASU/FT • 1.20 Installing a 3-IDC8/4 Initiating Device Circuit module • 1.22 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 10: General System Requirements And Special Considerations

    Market Place setting set to European and the Primary Language setting set to English U.K. • The term used for zones in test throughout the EST3 documentation is Service Groups. Points within a Service group must exactly match the points defined for each Zone.
  • Page 11 European Marketplace: Installation The EST3 life safety system has been approved/certified to EN 54-2, -4: 1997 by LPCB along with the following options with requirements: • output to fire alarm devices • alarm counter • fault signals from points •...
  • Page 12 Table 1-2: LPCB/EN-54-compliant ancillary products Model Description 3-ASU Audio Source Unit 3-FTCU Firefighters Telephone Control Unit 3-RCIC Rail Chassis Interface for ASU and FTCU 3-ZA20 20-watt Audio Amplifier 3-ZA40 40-watt Audio Amplifier EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 13 High and low voltage cabinet wiring Figure 1-1 shows a typical routing scheme for mains and battery wiring. Figure 1-2 shows typical wiring for all other wiring. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 14 1. All mains and battery wiring must be 600V/1.5 mm rated minimum. Battery #1 Battery #2 2. Double insulate all mains wiring. Figure 1-1: Typical routing diagram for mains and battery wiring EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 15 1. There are no limitations on wire types used for low voltage wiring to meet LPCB/EN-54 approval. Figure 1-2: Typical routing diagram for low voltage wiring EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 16: Ce-Compliant Systems

    Personal computers and auxiliary connected equipment. Class A systems are all other systems that satisfy the Class A limits but not the Class B limits. EST3 systems can be configured to meet both Class A and Class B requirements for emissions.
  • Page 17 Mains ac conductors do not require shielding or attaching Note: ferrite sleeves. In addition, take extra care to avoid damaging the RF gasket on the back box and cabinet door. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 18 Ferrite sleeve Ferrite sleeve Typical cabinet wire routing Ferrite sleeve Knockout Ground stud Proper shielding method for field wiring Figure 1-3: Typical wiring for CISPR Class B systems 1.10 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 19: Installing E Series Cabinets

    To install an E series cabinet: 1. Install the cabinet back box. Refer to the applicable back box installation sheet. 2. Install the cabinet doors. Refer to the applicable cabinet door installation sheet. EST3 International Installation Supplement Manual 1.11 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 20: Installing A Repeater/Remote Control Unit

    Do not attach a wire from earth to TB1-EGND • If used as a remote control unit (only user interface), power for remote control units must be supervised as shown in Figure 1-4 1.12 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 21 From DATA IN DATA OUT Signature controller To next device DATA IN DATA OUT or previous device Figure 1-4: 3-ANNCPU1 power supervision wiring for remote control units EST3 International Installation Supplement Manual 1.13 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 22: Installing The 3-Lcd Display Module

    To insert the 3-LKE labels: 1. Remove the slide locks from right side of the display module. See Figure 1-5. 2. Insert the 3-LKE labels. 3. Replace the slide locks. 1.14 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 23 Power Test Sounder Disable Fault Sounder Panel Reset Drill Off/On Silence Fire Fault Disable Monitor Previous Message Next Details Command Menus [3LKE_INSTALL.CDR] Figure 1-5: 3-LCD Display module installation EST3 International Installation Supplement Manual 1.15 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 24: Installing The 3-Ssdc Signature Device Controller Module

    A return wire pair and clamp a ferrite clamp (ordered separately, P/N RFK1) around each loop. See Figure 1-6. Field wiring should be thoroughly checked before making Note: connections to reduce the possibility of wiring faults. 1.16 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 25 An isolator may be installed anywhere on the loop but no more than 32 devices can be SIGA1 SIGA1 SIGA1 installed between isolators. Circuit 1 [SSDC_EURO_01.CDR] Figure 1-6: 3-SSDC installation and wiring EST3 International Installation Supplement Manual 1.17 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 26: Installing The 3-Aadc Addressable Analog Device Controller Module

    A return wire pair and clamp a ferrite sleeve (ordered separately, P/N RFK1) around each loop. See Figure 1-7. Field wiring should be thoroughly checked before making Note: connections to reduce the possibility of wiring faults. 1.18 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 27 An isolator may be installed anywhere on the loop but no more than 32 devices can be LOOP1 LOOP1 LOOP1 installed between isolators. Circuit 1 [SSDC_EURO_01.CDR] Figure 1-7: 3-AADC installation and wiring EST3 International Installation Supplement Manual 1.19 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 28: Installing The 3-Asu/Ft Audio Source Unit With Firefighter's Telephone

    • Attach a Kapton label over the communication LEDs on the 3-FTCU controller module Wiring the 3-ASU/FT Make field wiring connections as indicated on the 3-ASU/FT installation sheet. 1.20 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 29 250190 250192 BIN DIN 3-CHASS From FTCU J2 3-RCIC Notes: All wiring supervised. Ferrite clamps not required on a 3-ASU or 3-ASU/4. [3FTCU_EURO_01.CDR] Figure 1-8: 3-FTCU cabling diagram EST3 International Installation Supplement Manual 1.21 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 30: Installing A 3-Idc8/4 Initiating Device Circuit Module

    NAC IN Kapton label Ω 4.7K 1.5KΩ 1.5KΩ 1.5KΩ [IDC84SOFTSHORT.CDR] IDC/NAC IDC/NAC NAC IN 3-IDC8/4 IDC/NAC IDC/NAC NAC IN Typical initiating device circuit wiring Figure 1-9: 3-IDC8/4 typical installation 1.22 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 31 European Marketplace: Operation Summary This chapter provides instructions for operating the 3-LCD when the system is programmed for the European market place. For information not covered in this chapter, refer to the EST3 Systems Operation Manual. Content Introduction • 2.2 3-LCD display controls and indicators •...
  • Page 32 Fire event bin only after the panel is reset. System events that automatically restore are removed from their respective event bins once they are restored. The 3-LCD display operates as described in the EST3 System Operations Manual with the following notable exceptions: •...
  • Page 33 S1 T001 P01 C02 D0008 address NO DATA TO REPORT 0002 Fire Most recent, highest SMOKE, ADMIN BLDG, priority event 1ST FLR WEST F002 f000 D000 M001 [3SCRN7E.CDR] Figure 2-3: Expanded message display EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 34 Fault Sounder Panel Reset Drill Off / On Silence Fire Fault Disable Monitor Previous Message Next Details Command Menus [3LCDE.CDR] Figure 2-4: 3-LCD display module with European marketplace inserts EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 35 Note: Only one message is displayed regardless of how many zones are in test. To view zones in test, highlight the common zones in test message and press Details, then Next to view each zone in test. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 36 Numeric keypad Press a number key to select the menu option of the same number or enter the number for use in conjunction with other system functions. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 37 • The Reset switch is disabled as long as the alarm silence inhibit timer is running • The Reset switch does not affect disabled points or manually overridden functions. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 38 The pattern is determined by the project marketplace settings. When multiple events of different types come into the panel, the buzzer sounds the pattern for the highest priority event. EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 39 This chapter provides information required for certified technicians to properly assemble and install components in order to meet requirements for the Chinese marketplace. Content Wiring requirements for China systems • 3.2 EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 40 Green wire Blue wire Back box ground stud Filter Brown wire Blue wire G L1 L2 3-PPS/MON-230 [CHINASYS01.CDR] Figure 3-1: Wiring diagram showing high voltage wiring for China systems EST3 International Installation Supplement Manual Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...