EDWARDS SYSTEMS TECHNOLOGY EST2 Installation Sheets Manual

Hide thumbs Also See for EST2:

Advertisement

Quick Links

EST2
Installation Sheets
P/N 3100056 • Rev 1.0 • 30NOV00
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com

Advertisement

loading

Summary of Contents for EDWARDS SYSTEMS TECHNOLOGY EST2

  • Page 1 EST2 Installation Sheets P/N 3100056 • Rev 1.0 • 30NOV00 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 2 (941) 739-4300 COPYRIGHT NOTICE Copyright © 2000 Edwards Systems Technology, Inc. This manual is copyrighted by Edwards Systems Technology, Inc. (EST). You may not reproduce, translate, transcribe, or transmit any part of this manual without express, written permission from EST.
  • Page 3 2-WBDS(R) Outer Door and Inner Door 387218 2-WBS(R) Surface Mount Wallbox 387566 6ANN/B(-S) and 10ANN/B(-S) Remote Annunciator Cabinet Wallboxes 387586 CDR-3 Bell Coder 3100023 CMDN, SMDN, 2-CMDN(-C), 2-SMDN(-C) Enclosure Installation 270650 EST2 Component Installation Sheets Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 4 SIGA-APS(-220) Auxiliary Power Supply 387342 SIN-16 Remote Annunciator Input Receiver Module 387206 SLU-16R/Y Remote Annunciator Lamp Module 387203 SRU-8 Remote Annunciator Relay Module 387207 SWU-8(/3) Remote Annunciator Lamp and Switch Module 387204 EST2 Component Installation Sheets Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 5 Contents Introduction About this manual This manual contains copies of the EST2 installation sheets. The sheets are arranged in alphabetical order by title. The part number listed in Content is the installation sheet part number. The EST2 library A library of related documents supports the EST2 product line.
  • Page 6 Contents EST2 Component Installation Sheets Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 7 APPROVED BY: K. Patterson Outer door mounting hole DATE: 30MAR00 CREATED BY: B. Graham Washer EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 8 INSTALLATION Install the inner door. On the semi-flush mount wallbox On the surface mount wallbox Align the inner door mounting holes with the three Align the inner door mounting holes with the three inner door mounting studs on the wallbox. inner door mounting holes in the wallbox.
  • Page 9 CREATED BY: B. Graham Jumper Settings Related documentation: Installation and Service Manual EDWARDS SYSTEMS TECHNOLOGY, INC. Leave JP1 installed in the absence of a 2-TEL Firefighter Telephone. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 The removal of JP1 enables supervision for the 2-TEL option board.
  • Page 10 DIP SWITCH SETTINGS Mode Description Tones selected by S1 and S3 are available at TB1 and TB3 upon activation of the Audio Control Module. See the 2-TEL Boston code sequence (Evac channel only). installation sheet The signals connected to the auxiliary input terminals (TB4) are available at the output terminals (TB1 and TB3) upon activation of the Audio Control Module.
  • Page 11 2-SMDN-C See the related documentation listed in the title block for operator instructions on S2 Note: The remote alphanumeric display annunciators will only work with the EST2 fire alarm system. DS1(top) - DS4 (bottom) INSTALLATION SHEET: 2-CMDN(-C), 2-SMDN(-C) Remote Alphanumeric Display Annunciators...
  • Page 12 FIELD WIRING Ch 0 RS-485 Remote Alphanumeric Remote Alphanumeric Ch 1 Display Annunciator Display Annunciator (rear view) (rear view) Main 24 Vdc 24 Vdc Controller Module 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Class B next device...
  • Page 13 REVISION LEVEL: 2.0 APPROVED BY: B. Wanek Not used DATE: 22AUG00 CREATED BY: B. Graham Not used EDWARDS SYSTEMS TECHNOLOGY, INC. 2-ISO SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 2-ISO OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 14 MOUNTING INSTRUCTIONS Stud [1] Backbox [1] stud [2] footprint Mounting hole Standoff 6/32 x 3/8 pan head screw #6 interlocking washer *Wallbox *Mount the 2-CPU in a 6ANN/B(-S) or 10ANN/B(-S) wallbox. See the 6ANN/B(-S)/10ANN/B(-S) installation sheet for details Inner door (rear view) about the placement of power-limited wiring.
  • Page 15 INTERNAL WIRING Printer Wiring RS-485 Port Wiring Caution: Any wiring that exits one building and enters another requires a Ditek surge protector module. See the Network Supplement Manual. Pin Function To RS-485 port of Network Node Non-supervised RS-485 To RS-485 port of and power-limited Remote Annunciator RS-232...
  • Page 16 INTERNAL WIRING RPM wiring Notes RPM Jumper Settings Circuits* Alarm Supervisory Trouble Power-limited if the source is power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch (6.4 mm) from Separate TB1-3,4: TB1-7,8: TB1-5,6: power-limited wiring. Otherwise, use FPL, FPLP, FPLR, or an Circuits* Reverse Reverse...
  • Page 17 INSTALLATION PRODUCT INFORMATION The 2-DFK(R) is a trim kit that prepares double-wide wall Secure the wallbox to the frame. boxes for semi-flush mounting. The trim kit is available in two colors: grey or red(R). INSTALLATION Install the trim kit with the nuts provided. DIMENSIONS Top view Trim kit...
  • Page 18 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 19 Snap-top Standoff DATE: 30MAR00 CREATED BY: B. Graham Data Line Monitor Battery Battery EDWARDS SYSTEMS TECHNOLOGY, INC. Snap-on Circuit Board SARASOTA, FL: 941-739-4300 FAX 941-753-1806 Support (PST-6-01) CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Wallbox interior surface OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 20 FIELD WIRING 2-DLM back mounted in a network annunciator cabinet 24 Vdc 24 Vdc 24 Vdc RS-485 24 Vdc Listed primary power supply Remote Battery Cabinet 2-CPU RS-485 2-DLM CH2 + RS-485 Network CH1 + Main Controller Module Network Annunciator Cabinet Caution! Any wiring that exits one building and enters another requires a Ditek surge WB series cabinet...
  • Page 21 PRODUCT INFORMATION SPECIFICATIONS Description Voltage 5 Vdc, nominal Current 25mA The 2-ISO Isolator Module is an option card that mounts directly to Maximum line parameters 0.44 F/100 either a Main Controller Module or a 2-CPU. Its purpose is to Isolation 500 Vac provide electrical isolation between RS-485 devices and the control panel's primary power supply.
  • Page 22 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 23 APPROVED BY: J. Massing DATE: 29MAR00 CREATED BY: B. Graham Related documentation: Installation and Service Manual EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 24 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 25 DATE: 31MAR00 CREATED BY: B. Graham Ribbon Cable (P/N 250213) Related documentation: Installation and Service Manual EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 26 FIELD WIRING Notification Appliance Circuits (NACs) / Signature Data Circuit SDC Wiring Notes Legend Supervised. Signature Series module/pull station Power-limited when connected to a power-limited source. If the source is nonpower-limited, maintain a space of 1/4 inch (6.4 Signature Series mm) from power-limited wiring or use FPL, FPLP, FPLR, or an smoke detector equivalent in accordance with the National Electric Code.
  • Page 27 INSTALLATION PRODUCT INFORMATION The 2-LFK(R) is a trim kit that prepares the WB3 series Secure the wallbox to the frame. wall box for semi-flush mounting. The trim kit is available in two colors: grey or red(R). INSTALLATION Install the trim kit with the nuts provided. DIMENSIONS Top view Side view...
  • Page 28 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 29 Related documentation: Installation and Service Manual; System Operations Manual; SDU online help; LSRA-232/LSRA-PROG installation sheet Caution! EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Observe static-sensitive material handling practices. OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 30 INSTALLATION Removable access door Remove for LSRA-232 Configuration dip switch Mounting slot Life Safety Remote Annunciator (rear view) Connection Terminals Rx LED Tx LED 2 3 4 5 6 7 8 Table 1: DIP switch settings Description Switch positions S1-1 S1-2 S1-3 S1-4...
  • Page 31 WIRING Wiring the 2-LSRA(-C) to a Main Controller Module Ch 0 RS-485 Ch 1 + 24 Vdc Main Controller Module 1 2 3 4 5 6 7 8 9 2-LSRA(-C) rear view Provide physical separation between two wire bundles to ensure network survivability 24 Vdc Wiring required for...
  • Page 32 WIRING Wiring the 2-LSRA(-C) to a Network Main Controller Module RS-485 24 Vdc Network Main Controller Module 1 2 3 4 5 6 7 8 9 2-LSRA(-C) rear view 24 Vdc 1 2 3 4 5 6 7 8 9 2-LSRA(-C) rear view 24 Vdc 1 2 3 4 5 6 7 8 9...
  • Page 33 APPROVED BY: B. Wanek DATE: 24APR00 CREATED BY: B. Graham Related documentation: Installation and Service Manual EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 34 INSTALLATION Mount the Connect the Main ribbon cables Controller to the Main Module Controller Primary Power Supply Primary Power Supply with the Module. screws and washers Ribbon Cable provided. (P/N 250213) Main Main Controller Module Controller Module Ribbon Cable (P/N 250214) Expander Loop Module Main Ribbon Cable...
  • Page 35 INTERNAL WIRING RPM Wiring RPM Jumper Settings Notes Circuits* Alarm Supervisory Trouble Power-limited if the source is power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch (6.4 mm) from Separate TB1-3,4: TB1-7,8: TB1-5,6: power-limited wiring. Otherwise, use FPL, FPLP, FPLR, or an Circuits* Reverse Reverse...
  • Page 36 FIELD WIRING Notification Appliance Circuits (NACs) / Signature Data Circuit SDC Wiring Notification Appliance Circuits (NACs) / Signature Data Circuit SDC Wiring Notes Legend Supervised Signature Series module/pull station Power-limited if the source is power-limited. If the source is nonpower- limited, maintain a space of 1/4 inch (6.4 mm) from power-limited wiring.
  • Page 37 APPROVED BY: K. Johnson DATE: 22AUG00 CREATED BY: B. Graham Related documentation: Network Supplement Manual EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 38 INSTALLATION Mount the Connect the Network Main ribbon cables Controller to the Network Module Main Primary Power Supply Primary Power Supply with the Controller screws and Module. washers Ribbon Cable provided. (P/N 250213) Network Network Main Main Controller Controller Module Ribbon Cable Module (P/N 250214)
  • Page 39 INTERNAL WIRING RPM Wiring RPM Jumper Settings Notes Circuits* Alarm Supervisory Trouble Power-limited if the source is power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch (6.4 mm) from Separate TB1-3,4: TB1-7,8: TB1-5,6: power-limited wiring. Otherwise, use FPL, FPLP, FPLR, or an Circuits* Reverse Reverse...
  • Page 40 FIELD WIRING Notification Appliance Circuits (NACs) / Signature Data Circuit SDC Wiring Notes Legend Supervised Signature Series module/pull station Power-limited if the source is power-limited. If the source is nonpower- limited, maintain a space of 1/4 inch (6.4 mm) from power-limited wiring. Signature Series Otherwise, use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electric Code.
  • Page 41 APPROVED BY: J. Massing DATE: 30MAR00 CREATED BY: B. Graham WB3D(R) inner door (rear view) EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 42 WIRING 2-AAC 2-MIC (rear view) Note See the 2-AAC installation sheet for more information about the audio controller module. P/N: 387562 REV: 1.0 Page 2 of 2 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 43 (P/N 250213) REVISION LEVEL: 3.0 APPROVED BY: J. Massing DATE: 29MAR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 44 INSTALLATION Install the jumper for auxiliary power or 2-wire smoke Set the Smoke/Aux power select jumper. detectors on Signature UM modules with 2-SMKs. Remove the jumper for 4-wire smoke detectors. Settings In: Maintain continuous smoke/aux. power. 24 Vdc Aux output to 24 Vdc terminals of 4-wire smoke Out: Interrupt smoke/aux.
  • Page 45 INSTALLATION SHEET P/N: 387222 REVISION LEVEL: 2.0 APPROVED BY: J. Massing DATE: 30MAR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 46 WIRING Wire Stripping Guide Strip 1/4 inch from the ends of ALL wires that connect to the terminal blocks of the module. 1/4 inch (6.4 mm) Caution: more Exposing than 1/4 inch of wire may cause a ground fault. less Exposing than 1/4 inch of wire may result in a faulty connection.
  • Page 47 24 Vdc power. Related documentation: SAN-CPU installation sheet, SAN Series Annunciator Enclosures installation sheet Disable Europe EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Enable OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 48 INSTALLATION 1 Mount the 2-SANCOM. Note: See the related documentation listed in the title block for more information about specific mounting units. In a 4-unit or 8-unit enclosure On a 6-unit, 19-inch rack mount 2-SANCOM series series module module 2-SANCOM Side view Rear view Side view...
  • Page 49 Related documentation: Signature Series Component Installation Manual North American 2-1/2 inch (64 mm) deep 2-gang box Standard 4: Square 1-1/2 inch (38 mm) deep box EDWARDS SYSTEMS TECHNOLOGY, INC. European 100 mm square box SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075...
  • Page 50 FIELD WIRING SMOKE/AUX Select jumper 2-PPS 2-PPS/6A must be installed SMOKE/AUX NAC POWER POWER Power in Power in Maximum of Maximum of 1 volt drop 1 volt drop 2-SMK 2-SMK Power out Power out To compatible 2-wire To compatible 2-wire smoke detectors smoke detectors 3 2 1...
  • Page 51 DATE: 30MAR00 CREATED BY: B. Graham Related documentation: 2-AAC installation sheet; Signature Series Component Installation Manual EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 52 INSTALLATION 2-AAC without 2-TEL option board 2-AAC with 2-TEL option board Note: Remove JP1, on the 2-AAC to enable supervision for the 2-TEL option board. WIRING Typical telephone circuit 2-AAC Style Y (Class B) 2-TEL option board terminals 1 2 3 4 5 Terminal Function TB1-1...
  • Page 53 PRODUCT DESCRIPTION INSTALLATION The 2-WB(R) is a semi-flush mount wallbox, which is Mount the wallbox. available in two colors: grey or red (R). WIRE ROUTING Nail knockouts Primary Power Supply Main Controller Module Expander Loop Module Connect the cabinet to earth ground. Wallbox Ground lug Battery space...
  • Page 54 DIMENSIONS Typical conduit knockout Finished wall Top view Wall frame 11 in (27.9 cm) Side view 13 in (33.3 cm) 21 in (53.3 cm) 22.5 in (57.2 cm) Front view 16 in (40.6 cm) Typical conduit knockout Bottom view 4.5 in (11.4 cm) 14.125 in (35.9 cm) All conduit knockouts support 3/4 inch (1.9 cm)
  • Page 55 PRODUCT DESCRIPTION INSTALLATION The 2-WB3(R) is a surface mounted wallbox, which is Mount the wallbox. available in grey or red (R). The following subassemblies may be ordered to modify the wallbox. 2-LFK(R) trim kit for semi-flush mounting 2-WB3D/DF dead front door for the (red only) The dead front door does not include an inner door.
  • Page 56 DIMENSIONS Top view 11 in (27.9 cm) Side view Front view 22.875 in (58.1 cm) 29.9 in (75.94 cm) 16 in (40.6 cm) Bottom view 5.1 in (12.95 cm) All conduit knockouts support 3/4 inch All conduit knockouts support 3/4 inch (1.9 cm) (1.9 cm) conduit.
  • Page 57 INSTALLATION PRODUCT INFORMATION The 2-WB3D(R) is a set consisting of an outer door and Mount the operator instructions. two inner doors. The doors mount on a 2-WB3(R) wallbox The outer door is available in two colors: grey or red (R), Inner door (rear view) and has one Lexan viewing window.
  • Page 58 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 59 PRODUCT DESCRIPTION INSTALLATION The 2-WB7(R) is a surface mounted wallbox, which is Detail Mount the wallbox. available in grey or red (R). The following subassemblies Wallbox mounting hole may be ordered to modify the wallbox. 2-DFK(R) trim kit for semi-flush mounting 2-WB7D/DF dead front door for the (red only) The dead front door does not include an inner door.
  • Page 60 DIMENSIONS Typical conduit knockout Top view 24.13 in (61.3 cm) Side view Front view 20.35 in (51.7 cm) 29.9 in (75.94 cm) Typical conduit knockout 27.13 in (68.91 cm) Bottom view 5.33 in (27.93 cm) All conduit knockouts support 3/4 inch All conduit knockouts support 3/4 inch (1.9 cm) (1.9 cm)
  • Page 61 INSTALLATION PRODUCT DESCRIPTION The 2-WB7D(R) is a set consisting of an outer door and Mount the outer door. two inner doors. The doors mount on a 2-WB7(R) wallbox Mounting stud The outer door is available in two colors: grey or red (R), and has one Lexan viewing window.
  • Page 62 INSTALLATION Mount the operator instructions Upper inner door (front view) Operator instructions (P/N 260232) Grommet Plunger Plunger Grommet Upper inner door Operator instructions (P/N 260232) Related Documentation See the following installation sheets for the mounting of inner door components: Liquid Crystal Display (P/N 270212) LED/Switch modules (P/N 270214)
  • Page 63 INSTALLATION PRODUCT INFORMATION The 2-WBD(R) is a set consisting of an outer door and an Mount the operator instructions. inner door. Both doors mount on a 2-WB(R) wallbox . The Inner door (rear view) outer door is available in two colors: grey or red (R), and has one Lexan viewing window.
  • Page 64 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 65 INSTALLATION PRODUCT INFORMATION The 2-WBDS(R) is a set consisting of an outer door and Mount the operator instructions. an inner door. Both doors mount on a 2-WBS(R) wallbox Inner door (rear view) The outer door is available in two colors: grey or red (R), and has one Lexan viewing window.
  • Page 66 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 67 PRODUCT DESCRIPTION INSTALLATION The 2-WBS(R) is a surface mount wallbox, which is Mount the wallbox. available in two colors: grey or red (R). WIRE ROUTING Primary Power Supply Main Controller Module Connect the cabinet to earth ground. Expander Loop Module Wallbox Ground lug Grounding strap...
  • Page 68 DIMENSIONS Top view Typical conduit knockout 11 in (27.9 cm) Side view Front view 13.1 in (33.3 cm) 22.5 in (57.2 cm) Typical conduit knockout 16 in (40.6 cm) 5.1 in (12.95 cm) Bottom view All conduit knockouts support 3/4 inch (1.9 cm) conduit.
  • Page 69 (33.5 cm) REVISION LEVEL: 1.0 APPROVED BY: K. Patterson DATE: 07DEC99 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 70 DIMENSIONS 10ANN/B(-S) Semi-flush 23.86 in (60.60 cm) 2.75 in (6.99 cm) 25.47 in (64.7 cm) 12.1 in (30.73 cm) 13.19 in (33.5 cm) Surface mount 2.75 in (7.0 cm) 25.47 in (64.7 cm) 13.19 in (33.5 cm) All conduit knockouts support 3/4 inch (1.9 cm) conduit.
  • Page 71 FILE NAME: 3100023.CDR REVISION LEVEL: 1.0 APPROVED BY: R. Wolf DATE: 17APR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Enclosure OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 72 DIP SWITCH SETUP Function DIP Switch Position [1] indicates that the DIP switch Temporal Tone does not apply to March Tones the function. Fast (90 beats per minute) [2] The On position Slow (60 beats per minute) configures the Code Operations CDR-3 to generate march tones upon Normal 4-digit code...
  • Page 73 APPROVED BY: K. Patterson BP-A SAN blank panel DATE: 30MAR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 74 DIMENSIONS Six module mounting frame Front view 10.5 in (26.7 cm) 19 in (48.3 cm) Eight module enclosure 22.37 in (56.8 cm) Top view Knockout for 0.75 in (1.9 cm) conduit (both sides) 1.4 in (3.6 cm) Cover 27.41 in (69.6 cm) Front view 11.5 in 9.5 in...
  • Page 75 REVISION LEVEL: 4.0 APPROVED BY: M. Slack spacer DATE: 24AUG00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 Main Controller Module CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 76 WIRING Notes Connect J1 and J2 to RJ31X or RJ38X telephone jacks installed by an authorized telephone company representative (CA31A or CA38A in Canada). Install the RJ31X (RJ38X) jacks within 5 ft (1.5 m) of the control panel and allow two extra feet of cable for a total of 7 ft (2.13 m). The dialer installation kit includes a protective bushing (P/N 362316) for enclosure knockouts.
  • Page 77 DIALER PROGRAMMING Notes A confirmation tone indicates the correct entry of a program item. Phone lines must be loop start on a public-switched network. PBX, party lines, and ground start lines are not acceptable. The dialer does not place calls, monitor the panel, or monitor the phone lines during the programming process. After initial programming, the dialer notifies the central monitoring station that it is disabled before programming can proceed.
  • Page 78 Programming 1 or 2 line operation (item 05) Press the following telephone keys: Listen for the confirmation Make sure that the status LED Enter 01 or 02 on the tone to verify that you displays a steady green pattern telephone keypad. The interrupted by rapid amber default setting is 2.
  • Page 79 8 green / 8 yellow alternating LED/switch pairs Related documentation: 2-LCD installation sheet Blank plate option 2-FBP Switches Momentary push button EDWARDS SYSTEMS TECHNOLOGY, INC. ° ° SARASOTA, FL: 941-739-4300 FAX 941-753-1806 Temperature range 32 to 120 F (0 to 49 C)
  • Page 80 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 81 The IOP3A provides two isolated RS232 connections, as well as a DB9 and RJ12 connector for downloading. A select mode allows both a printer and modem to be connected when used on EST2 systems. JUMPER SETUP The IOP3A should be used in ALL applications which...
  • Page 82 APPLICATION DRAWINGS IOP3A to CM motherboard wiring IOP3A to 3-CPU1 wiring 3-CPU1 Panel controller +24 VDC COMMON IOP3A 24 Vdc Switch shown in UP position. Switch shown in UP position. CM Motherboard IOP3A JB2 INSTALLED (PROVIDES 12V TO POWER MODEM) GREEN GREEN GREEN...
  • Page 83 APPROVED BY: K. Johnson DATE: 22AUG00 CREATED BY: B. Graham Related documentation: SAN-CPU installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 84 INSTALLATION INSTRUCTIONS Note: ISP96 series panels require 5.25 inches of vertical height and 2 inches of rear clearance in the enclosure. ISP96 series panel 19-inch rack Screw FIELD WIRING ISP-96 (rear view) SAN-CPU terminals (See Table 1 and Detail A.) See Table 1 and Detail B.
  • Page 85 FIELD WIRING Table 1: ISP-96 data line wiring (SAN-CPU terminals) TB1-1 +24 Vdc TB1-2 24 Vdc common Format Class B (Style 4) Class A (Style 7) Notes RS-485 TB1-3 RS-485 TB1-3 RS-485 Install JP1/JP2 if the SAN-CPU is the last device on TB1-4 RS-485 TB1-4...
  • Page 86 ISP96 ADDRESSING Matrix A Matrix B Matrix C Notes All switches and LEDs are independently programmed and controlled. Therefore, the addresses for the upper switch positions and the lower LEDs are different even though they appear to be the same. Matrix A Switches LEDs...
  • Page 87 INSTALLATION LSRA-PROG Programing Port RS-232 RJ12 Jack Remove the access door on the rear of the annunciator. LSRA-PROG Firmly mate the LSRA-PROG's Programming Port connector with the connector on the annunciator circuit board. Connect modular cable from RJ12 jack Annunciator on the LSRA-PROG to the PC adapter.
  • Page 88 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 89 DATE: 30MAR00 CREATED BY: B. Graham The RACCDR is a red, dead front outer door that mounts EDWARDS SYSTEMS TECHNOLOGY, INC. on the RACCR wallbox. The RACCDR does not include SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 an inner door.
  • Page 90 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 91 FILE NAME: 387578.CDR REVISION LEVEL: 1.0 APPROVED BY: J. Massing DATE: 30MAR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 92 Technical Manuals Online! - http://www.tech-man.com firealarmresources.com...
  • Page 93 Locking pin REVISION LEVEL: 4.0 APPROVED BY: K. Johnson DATE: 24AUG00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 94 INSTALLATION INSTRUCTIONS Replacing paper Figure 2: Paper replacement Note: Do not remove power from the printer to replace paper. Paper To replace the paper: take-up Paper slot reel Remove the printed paper from the take-up reel (Figure 2). Remove the empty paper roll and spindle from the printer cradle. Install the spindle in the new paper roll.
  • Page 95 JUMPER SETTINGS Notes Table 1: FCOM card requirements and jumper settings Install JP1 and JP2 on FCOM-485 cards. Outgoing format RS-232 RS-485 20 mA loop Fiber optic Incoming format Install JP1 and JP2 on FCOM-FIB cards in RS-232 P1: FCOM-232 P1: FCOM-232 P1: FCOM-232 P1: FCOM-232...
  • Page 96 APPLICATION FLOWCHART Use this flowchart to determine the FCOM card Is the placement and the jumper settings on the printer. signal sent See the Jumper Settings in Table 3. Set jumpers to another Start at 000001. printer? incoming Install FCOM-232 signal format in P1.
  • Page 97 FIELD WIRING Printer-to-printer connection DCPU to printer Printer 1 Printer 2 Printer 3 Printer 32 DCPU Printer connector P1 Control module* FCOM-232 FCOM-232 CH A CH B CH A CH B *Control modules include network controllers (CM1[N]/CM2[N][D]), 2-CPU modules, and main controller modules (MCM[N] series Control modules provide only RS-232 format.
  • Page 98 FIELD WIRING Printer to printer (no format change) Printer to printer (format change) Printer connector P1 Printer connector P1 Printer connector P2 Printer connector P1 FCOM-232 FCOM-232 FCOM-232 FCOM-232 CH A CH B CH A CH B CH A CH B CH A CH B 50 ft max.
  • Page 99 APPROVED BY: K. Patterson DATE: 30MAR00 CREATED BY: B. Graham Pem stud Lock nut EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 100 DIMENSIONS Six module mounting frame 10.5 in (26.7 cm) Front view 19 in (48.3 cm) Four module enclosure Knockout for 11.25 in(28.6 cm) 0.75 in (1.9 cm) conduit (both sides) Top view 2.5 in (6.4 cm) 1.4 in (3.6 cm) Front door 16.25 in (41.3 cm) Side view...
  • Page 101 APPROVED BY: J. Massing DATE:30MAR00 CREATED BY: B. Graham SAN Series Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 102 WIRING 24 Vdc from the primary power supply or power riser RS-485 data line from the previous panel Ch 1 Required for Class B (Style 4) and Class A (Style 7) RS-485 data line from the previous panel Ch 2 24 Vdc to the next SAN annunciator or auxiliary module power RS-485 data line to the next panel...
  • Page 103 Related documentation: SAN-CPU installation sheet Height 8.875 in (22.5 cm) Width 2.75 in (7.0 cm) EDWARDS SYSTEMS TECHNOLOGY, INC. Depth 2.75 in (7.0 cm) SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 104 INTERNAL WIRING Warning! N.O. local ACTIVATE ALARM alarm contact Disconnect power to cabinets before installing or N.O. local SILENCE removing components. Failure to do so may result in silence switch serious injury or loss of life. STEADY WHOOP SELECT TS1 (-) N.O.
  • Page 105 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 Side view...
  • Page 106 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Note: If the SDR-32(K) is the last module, Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. install the continuity Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.
  • Page 107 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 Side view...
  • Page 108 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.
  • Page 109 Pins 1 and 2: 70 Vrms installation sheet, RACCR Remote Audio Closet Cabinet installation sheet Pins 2 and 3: 25 Vrms EDWARDS SYSTEMS TECHNOLOGY, INC. In: TB5 signal before 1 kHz backup tone SARASOTA, FL: 941-739-4300 FAX 941-753-1806 Out: 1 kHz backup tone before TB5 signal...
  • Page 110 WIRING 25 Vrms input wiring Wire the amplifier JP3 on reverse side Connect the power, the Signature Data To the Ch 1 input of the 25 V Circuit (SDC) , the input risers, and the next amplifier backup risers as required. 25 V From the Ch 1 output of the Test the circuit before you connect the...
  • Page 111 INSTALLATION SHEET P/N: 387342 REVISION LEVEL: 2.0 APPROVED BY: J. Massing DATE: 30MAR00 CREATED BY: B. Graham EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 112 WIRING Wire Stripping Guide Strip 1/4 inch from the ends of ALL wires that connect to the terminal blocks of the module. 1/4 inch (6.4 mm) Caution: more Exposing than 1/4 inch of wire may cause a ground fault. less Exposing than 1/4 inch of wire may result in a faulty connection.
  • Page 113 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Side view Front view OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 114 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Note: If the SIN-16 is the last module, Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. install the continuity Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.
  • Page 115 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 Side view Front view OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 116 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.
  • Page 117 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. Side view Front view SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 INTERNATIONAL, CANADA: 905-270-1711 FAX 905-270-9553 Technical Manuals Online! - http://www.tech-man.com...
  • Page 118 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Note: If the SIN-16 is the last module, Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. install the continuity Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.
  • Page 119 APPROVED BY: J. Massing DATE: 31MAR00 CREATED BY: B. Graham Related documentation: SAN Series Remote Annunciator Enclosures installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 941-739-4300 FAX 941-753-1806 CHESHIRE, CT: 203-699-3000 FAX 203-699-3075 OWEN SOUND, CANADA: 519-376-2430 FAX 519-376-7258 Side view...
  • Page 120 INSTALLATION Make the ribbon cable connections. Plug the ribbon cable assembly (P/N 250080) from P1 of the SAN-CPU into P2 of the 2-SANCOM. Plug the ribbon cable from P1 of the 2-SANCOM to P2 of the next SAN series module. Plug the ribbon cable from P1 of each SAN module to P2 of the next SAN module until you reach the last one.