LG DU-52SZ61D Service Manual page 11

Chassis nb-04aa
Hide thumbs Also See for DU-52SZ61D:

Advertisement

(4) Select program options.
(5) Check the [Erase before programming] and [Verify] menu
as shown <Fig. 12> and press the OK button.
(6) At this time, the download starts. The download will finish
in about 10 seconds.
<Fig . 12>
9. Gemstar VBI Micom Download
9-1. Preparation for Adjustment
(1) As shown below, connect the MPLAB ICD2 equipment, PC
and Digital Connector.
(2) Turn on the MPLAB ICD2 POWER Supply.
(3) After turning on the PC and MONITOR, select the 'MPLAB
IDE' from the screen.
Connect the RS-232 or USB Cable
Connect the MPLAB ICD2 and connector of Digital Board
9-2. Adjustment Sequence
(1) Once the program is executed, select the MPLAB ICD2
from "Programmer -> Select Programmer".
All manuals and user guides at all-guides.com
ADJUSTMENT INSTRUCTIONS
CN1201
+13V
+5V
IC1204
GND
VIB Micom
Data
Clock
<Digital Board>
- 11 -
(2) Select "Configure -> Select Device".
(3) When the "Select Device" window appears, select the
PIC18F1220 from "Device" and press OK.
(4) Select "Programmer -> Connect".
When connected with the Micom, the display message on
the Output window appears as below.
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to MPLAB ICD 2
Target Device PIC18F1220 found, revision = 0x4
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 Ready