A gas leak could occur. If you move the appliance after
the gas supply has been established, a gas leak could
occur.
Do not move the appliance once the gas supply is
connected.
If you move the appliance, check that the connec-
tions are not leaking.
For your safety (only for ZA)
This appliance is adjusted to operate on LPG only.
Do not tamper or modify the appliance.
Burn back
¡ Fire in burner tube or chamber.
¡ In the event of a burn-back, where the flame burns
back to the jet, immediately turn the gas supply off
at the control valve on the panel.
¡ After ensuring the flame is extinguished, wait for 1
minute and re-light the appliance in the normal man-
ner.
¡ Should the appliance again burn back, close the
control valve and call a service technician. Do not
use the appliance again until the service technician
has declared that it is safe to do so.
Gas-pressure regulator
¡ This appliance requires an operating pressure of
2,8 kPa at the appliance.
¡ A suitable LPG regulator that complies with the re-
quirements of SANS 1237 must be installed.
Important information for the user:
Note: This appliance may only be installed by a re-
gistered SAQCC Gas installer.
¡ All registered installers are issued with a card carry-
ing their registration number. Ask to be shown the
card before allowing the installation work to com-
mence and make a note of the installer registration
number.
¡ Upon completion of the installation, the installer is
required to explain the operational details of the ap-
pliance together with the safety instructions.
¡ You will be asked to sign acceptance of the installa-
tion and be provided with a completion certificate.
You should only sign for acceptance of the installa-
tion when the installation is completed to your satis-
faction.
¡ Note that your invoice is required in the event that
you wish make a guarantee claim.
Important information for the installer:
¡ This appliance may only be installed by a gas in-
staller registered with the South African qualification
and certification committee (SAQCC).
¡ The appliance must be installed in accordance with
the requirements of SANS 10087-1 for use with
LPG, SANS 827 for use with NG and any fire depart-
ment regulations and/or local bylaws applicable to
the area. If in doubt, check with the relevant author-
ity before undertaking the installation.
¡ Upon completion of the installation you are required
to fully explain and demonstrate to the user the op-
erational details and safety practices applicable to
the appliance and the installation.
Caution
The primary air intake adjuster is set at the factory for
the set gas and must not be reset or tampered with,
this must only be set by an authorized BSH technician.
No modifications to the primary air is allowed to be
done. Please check the rating label for the type of gas
to be used.
4.2 Electrical connection
The appliance must be connected by an authorised
specialist. You must comply with the requirements of
your electricity supplier.
¡ Your appliance is designed to operate at 220–
240 V. A 16 A fuse is required for connection.
¡ If the electricity supply drops below 180 V, the elec-
trical ignition system does not work.
¡ If the power cord of this appliance is damaged, it
must be replaced by the manufacturer, the manufac-
turer's Customer Service or a similarly qualified per-
son in order to prevent any risk.
¡ Any damage arising from the appliance being con-
nected incorrectly will invalidate the warranty.
Information on electrical connection by our customer
service:
¡ Connect the appliance in accordance with the spe-
cifications on the rating plate.
¡ The appliance must only be connected to an elec-
trical connection that corresponds to the applicable
regulations. The socket must be easily accessible
so that you can disconnect the appliance from the
electricity supply if necessary.
¡ Ensure that a multi-pin disconnecting system is
available.
¡ For safety reasons, this appliance must only be con-
nected to an earthed connection. If the safety earth
terminal does not comply with regulations, protec-
tion against electrical risks is not guaranteed.
¡ To connect the appliance, use H 05 VV-F cables or
other equivalent cables.
Important information about the electrical
connection
Note the following information and ensure that:
WARNING ‒ Risk of electric shock!
There is a risk of electric shock if you touch live com-
ponents.
Hold the mains plug with dry hands only.
Never pull out the mains plug from the socket while
the appliance is in operation.
Pull out the power cable directly at the plug and
never by pulling the power cable as this may be-
come damaged.
¡ Fit the mains plug and socket together.
¡ The mains plug can be accessed at all times.
¡ The cross section of the cable is sufficient.
¡ The mains cable is not kinked, crushed, modified or
severed.
¡ If required, the mains cable must only be replaced
by a qualified electrician. A replacement mains
cable is available from the after-sales service.
¡ Do not use any multiple plugs or multi-connectors
and extension cords.
¡ The earthing system is correctly installed.
¡ If using a residual current device, only use one that
bears the mark
​ ⁠ . The presence of this mark is the
only way to be sure that it fulfils all the applicable
regulations.
Installation and connection en