Measurements And Adjustments; Voltage Chart Of A-Board; Voltage Chart Of P-Board - Panasonic TH-L32E3R Service Manual

Table of Contents

Advertisement

8 Measurements and Adjustments

8.1.

Voltage chart of A-board

Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
8.2.

Voltage chart of P-board

Set IP-Board to a dummy set and check the satisfaction with the specified voltage as following table.
VOLTAGE
PFC390V
LED24V
DTV16V
STBY6V
POWER SUPPLY NAME
MEASUREMENT POINT
SUB1.8V
SUB1.2V
SUB3.3V
SUB5V
STB5V
SUB1.5V
TEST POINT
TP7201, 7202
TP7514, 7515
TP7503, 7504
TP7501, 7502
SPECIFICATION
TP8700
1.74 - 1.90 V
TP8100
1.18 - 1.32 V
TP8701
3.19 - 3.46 V
TP8702
4.75 - 5.25 V
TP5400
4.9 - 5.1 V
TP8101
1.4 - 1.6 V
SPECIFICATION (V)
390 ± 15
24 ± 2
16 ± 1.5
5.8 ± 0.8
5.8 ± 0.8
23
STATE
Reception
* HOT
Reception
Reception
Reception
Stand by