Download Print this page

Advertisement

Quick Links

Millennium Technologies
SERIAL TO ETHERNET (TWO PORT)
MODEL No: SERETH-2P
VER 1.0
MILLENNIUM TECHNOLOGIES
440, MASTER MIND 1,
ROYAL PALMS ESTATE'
AAREY MILK COLONY,
GOREGAON (EAST),
MUMBAI-400065.
INDIA.
PH: - 91-22-65229736,
91-22-28794703
SERETH-2P.doc, Ver1.0
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SERETH-2P and is the answer not in the manual?

Questions and answers

Summary of Contents for Millennium SERETH-2P

  • Page 1 Millennium Technologies SERIAL TO ETHERNET (TWO PORT) MODEL No: SERETH-2P VER 1.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE’ AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736, 91-22-28794703 SERETH-2P.doc, Ver1.0...
  • Page 2: Table Of Contents

    Millennium Technologies Table of Contents INTRODUCTION..................3 1.0.1 PRODUCT DESCRIPTION ................3 1.0.2 FEATURES....................3 1.0.3 SPECIFICATIONS ..................3 1.0.4 DIP SWITCH SETTINGS: ................3 SOFTWARE INSTALLATION ..............4 DEVICE CONFIGURATION...............6 4.0 Configuration Parameters ................11 SERETH-2P.doc, Ver1.0...
  • Page 3: Introduction

    115200 Core Module Memory 64KB Flash, 4KB RAM Ethernet 10/100Mbps Dimension 95x90x50 mm Power Consumption 50mA@24V, 2Watt max. 1.0.4 DIP SWITCH SETTINGS: For both DIP switches SERIAL SWITCH POSITION RS-232 1-ON 2,3,4-OFF RS-485 1,3,4-OFF 2-ON RS-422 1,4-OFF 2,3-ON SERETH-2P.doc, Ver1.0...
  • Page 4: Software Installation

    The installation steps are as follows: Click “OK” to continue to the next window. The software gets installed in default directory. If you want to change the directory, click on “Change Directory” and specify the path. SERETH-2P.doc, Ver1.0...
  • Page 5 Millennium Technologies Click on “Continue” Installation is about to finish. Click on “OK” button to finish the installation. SERETH-2P.doc, Ver1.0...
  • Page 6: Device Configuration

    IP address, subnetmask, gateway etc. can be set using this utility. These settings are stored in permanent flash memory of the board. To run the utility, click on Start/Program/Millennium Following screen will appear on the PC. Please follow the steps to install the device correctly.
  • Page 7 So it will display all the devices which are in the network. If you want to change the configuration settings of any of the searched device then select that device and click on the “Configuration” icon(Right most) or Double click on that device in the list. Look at the screen below. SERETH-2P.doc, Ver1.0...
  • Page 8 Millennium Technologies So clicking on “Configuration” icon will open Configuration window, where one can change IP address, subnet, gateway and other parameters. Shown in following window. SERETH-2P.doc, Ver1.0...
  • Page 9 IP address of the device before. Put the IP address of the device and Click “OK”.It will start searching by the IP address given and will display the corresponding DIN, IP address etc. See the following screen SERETH-2P.doc, Ver1.0...
  • Page 10 Millennium Technologies SERETH-2P.doc, Ver1.0...
  • Page 11: Configuration Parameters

    2. Client Mode: In this mode device will act as a client and PC software as a server. While selecting this mode you need to specify destination IP i.e. IP address of PC to which you want to communicate. SERETH-2P.doc, Ver1.0...