Reconnection interval—Interval for the OpenFlow switch to wait before it attempts to reconnect to a
controller.
To set OpenFlow timers for an OpenFlow switch:
Step
1.
Enter system view.
2.
Enter OpenFlow instance
view.
3.
Set the connection detection
interval.
4.
Set the reconnection interval.
Configuring an OpenFlow instance to support
dynamic MAC addresses
You can configure an OpenFlow instance to support querying and deleting of dynamic MAC addresses
in MAC-IP flow tables.
To configure an OpenFlow instance to support dynamic MAC addresses:
Step
1.
Enter system view.
2.
Enter OpenFlow instance
view.
3.
Configure the OpenFlow
instance to support dynamic
MAC addresses.

Displaying and maintaining OpenFlow

Execute display commands in any view.
Task
Display the detailed information for an OpenFlow
instance.
Display flow table entries for an OpenFlow instance.
Command
system-view
openflow instance instance-id
controller echo-request interval
interval-value
controller connect interval
interval-value
Command
system-view
openflow instance instance-id
mac-ip dynamic-mac aware
Command
display openflow instance [ instance-id ]
display openflow instance instance-id flow-table
[ table-id ]
11
Remarks
N/A
N/A
By default, the connection
detection interval is 5 seconds.
To reduce the CPU load, H3C
recommends that you set the
connection detection interval to a
large value.
By default, the reconnection
interval is 60 seconds.
Remarks
N/A
N/A
By default, an OpenFlow instance
prohibits controllers from querying
and deleting dynamic MAC
addresses.

Advertisement