Outdoor Unit - Roland FAVORITE ON-OFF Series Service Manual

Table of Contents

Advertisement

1.3.2

Outdoor Unit

Evacua�on for the whole system
(/TJUUX [TOZ)
<GI[[S V[SV
Procedure:
1.
Confirm that the 2- and 3-way valves are opened.
2.
Connect the vacuum pump to the 3-way valve's
service port.
3.
Evacuate the system for approximately one hour.
Confirm that the compound meter indicates
-0.1 MPa (14.5Psi).
Page 20
(2OW[OJ YOJK)
(-GY YOJK)
56+4
2U
.O
:]U-]G_ \GR\K
:NXKK-]G_ \GR\K
)259+
4.
Close the valve (Low side) on the charge set and turn
off the vacuum pump.
Wait a period of five minutes then check whether the
5.
gauge needle moves a�er turning off the vacuum
pump.
6.
Disconnect the charge hose from the vacuum pump.
(5[ZJUUX [TOZ)
5VKT
5VKT