Known Issues

WebUI starts before ReaderService™

ReaderService™ takes a couple of minutes longer to start than the WebUI. If the WebUI is accessed
during this time, it results in the error message:
"Failed to connect to reader service
at http://<<ip_address>>:19040".
It's recommended to wait a couple of minutes and then refresh
the page to try again.

USB connection interferes with ReaderService™

If a USB cable is plugged in, the reader module does not communicate properly. When
ReaderService™ attempts to use the module in this state, it results in the error message: "Problem
connecting reader - Error while trying to query Reader Information. Invalid Reader Serial Number;
Serial = null". If this occurs, ensure the USB cable is disconnected and then try reconnecting.