Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
1. Stop unit and be sure no air pressure is in the oil reservoir.
2. Disconnect, tag and lock out the power supply to the starter.
3. Remove the spin-on element.
4. Clean the gasket face of the filter body.
5. Coat the new element gasket with clean lubricant used in the unit.
6. Screw new element on filter body and tighten clockwise by hand 3/4 turn after contact. DO NOT
OVERTIGHTEN ELEMENT.
7. Reset the filter life setting to 1000 hours, see "Maintenance Adjustments" in Controller Operating and
Service Manual.
8. Run the unit and check for leaks.
Figure 5-5 – OIL FILTER
13-20-600
Page 58