3) Wire the power AC connection to the terminals.
Wire Color: According to American and Europe standard requirements --
American standard: L: Black; N: White; G: Green
Europe standard: L: Brown; N: Blue; G: Green&Yellow
Note!
FB1, FB2 are used to remotely display the on and off states of the switch. When the switch is closed, FB1 is connected to
FB2; when the switch is open, FB1 is disconnected from FB2.
Resistor is selected according to supply voltage, to ensure circuit current less than the rated current of the Indicator light
and <320mA
4) Wire the string cables to the interface.
Note!
Please follow the marks (1+, 1-, 2+, 2- ) for PV wiring.
5) Note the installation environment (See the schematic on the next page).
Note!
Do not expose to direct sunlight.
Do not expose to rain and snow cover.
Do not be in direct contact with (continuous) ingress water.
The installation site must have good ventilation condition.
L
American
Europe
Emergency Button (Optional)
N
G
4
www.projoy-electric.com