Summary of Contents for Transforming Technologies SCION IN1200 Series

  • Page 1 T R A N S F O R M I N G T E C H N O L O G I E S , L L C Model IN1200 Series Instruction Manual...
  • Page 2 SCION IN1200 - Ionizing Bar Operation Manual The SCION IN1200 ionizing bar is an effective tool to eliminate static in the electronics, plastics, chemicals, printing, textile, optical and other in- dustries. Utilizing AC Square Wave Technology, the SCION IN1200 deliv- ers uniform streams of ionized air that quickly eliminates static charge.
  • Page 3 75% 5. Do not use this device in combustible and explosive environments. 6. Electrodes must not come in contact with metal conductors. 7. Please contact Transforming Technologies Customer Service for repair information. Installation 1. Choose optimal location for ionization and mount the bar and power supply.
  • Page 4 Air Assist Attach the IN1200 to the gas line using the appropriate tubing. The IN1200 comes with a 1/4” quick release connector. Adjust pressure as required. The time required to neutralize a static charge on an item in this area de- pends on two important factors: distance to the ionizer and air velocity assist.
  • Page 5 The ion bar will issue an alarm (Alarm 1) on the LED if a HV error occurs. The error is a result of an issue with the high voltage current flowing through the bar. If an HV error occurs, turn of the ion bars power and con- tact Transforming Technologies at 419-841-9552.
  • Page 6 Maintenance The electrodes must be regularly cleaned to maintain good ionizing per- formance. Frequency of cleaning is dependent on the cleanliness of the environment and requirements of the ESD program. At least once a month is a suggested frequency. Note: Do not clean ionizer when pow- ered on.
  • Page 7 Transforming Technologies. The com- pany does not warrant damage due to misuse, neglect, alteration or acci- dent. In no event shall Transforming Technologies be liable for collateral or consequential damages. To receive service under warranty, please contact Transforming Technologies Technical Support.
  • Page 8 3719 King Rd | Toledo, OH 43617 | P: 419-841-9552 | F: 419-841-3241 | info@transforming-technologies.com...