Download Print this page
Transforming Technologies BFN 803 Instruction Manual

Transforming Technologies BFN 803 Instruction Manual

Ac ionizer

Advertisement

Quick Links

T R A N S F O R M I N G
T E C H N O L O G I E S ,
L L C
O
U
T
S
T
A
N
D
I
N
G
A
L
T
E
R
N
A
T
I
V
E
S
I
N
S
T
A
T
I
C
C
O
N
T
R
O
L
BFN 803 Ionizing Blower
Instruction Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the BFN 803 and is the answer not in the manual?

Questions and answers

Summary of Contents for Transforming Technologies BFN 803

  • Page 1 T R A N S F O R M I N G T E C H N O L O G I E S , L L C BFN 803 Ionizing Blower Instruction Manual...
  • Page 2: Table Of Contents

    Contents BFN 803 BFN Series Description Features Specification Operating Guide Dis/Assembly Periodic Verification About Service/ warranty Transforming Technologies...
  • Page 3: Bfn Series

    Description Series Ionizers ® Dependable, Balanced and Fast. BFN® AC ionizers, from Transforming Technologies, are built to last. Reliable AC ionization technology is combined with superior mechani- cal design to assure years of optimal static neutralizing performance.  A full 1 year warranty.
  • Page 4: Features

    Description Please read these operating instructions thoroughly be- fore operating the BFN 803 unit. All BFN series devices require a grounded power source for proper operation. BFN series products are NOT suitable for use in flamma- ble or explosive environments.
  • Page 5 Finish fan speed on high Powder coat, off white Temperature 32-122° F (0-50° C) Approvals RH operating range 20-60%, non-condensing Packing list:  BFN 803 ionizing blower  Power cord  Instruction manual  Certificate of Conformance  Mounting Brackets...
  • Page 6: Operating Guide

    BFN 803 Performance Discharge time in seconds (1000 volts to 100volts) de- termined per EOS/ESD Asso- ciation Stan- dard NO.3; unit at 18” above test plate, fans at high speed. Discharge times are slightly loner for 230VAC, Tested in accord with ANSI/ESD STM3.1-2006 50Hz unit.
  • Page 7: Dis/Assembly

    Operating Guide Cont. 2. Periodic Maintenance The only maintenance required for BFN series ionizers is the periodic cleaning of the emitter points, inlet and out- let finger guards and the fan assembly. Emitter point cleaning affects the static decay ability of the ionizer and is important for maintaining its optimal performance.
  • Page 8 Air Outlet Disassembly Cont. B. Lightly pull the front cover downwards until it separates from the blower. C. Completely remove cover and set aside. Air Inlet Disassembly A. Press the recessed release point on the bottom of the plastic rear cover using a flat blade screw- driver.
  • Page 9 Internal Fan Cleaning After removing both front and rear fan guards, the emit- ter points and fan assembly will be unobstructed, for easy deep cleaning. Use a soft brush, Isopropyl Alcohol and compressed air to remove any foreign matter. Note: The frequency of cleaning required for optimal per- formance from BFN ionizers depends on the environment in which the BFN series ionizer operates.
  • Page 10: Periodic Verification

    Caution: BFN series products have safety re- lay switches where the front and rear fan guards attach to the unit. These relays dis- able the fan/ionizer operation when either fan guard is removed. Take care when attach- ing the fan guards to assure proper function- ing of the product.
  • Page 11: Transforming Technologies

    Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Transforming Technologies be liable for collateral or conse- quential damages. To receive service under warranty, please contact Transforming Technologies Technical Sup- port.