Download Print this page

Baso 120-2 Manual page 6

Test kit for mv gas equipment

Advertisement

* "X" Range applies anly to controls or power units identified by this suffix after the
part number. All controls used with Thermocouple longer than 72" must be of the
proper "X" dropout range. Do not use "X' controls with Thermocouples less than
72" in length.
6
V
BASO MODEL
NUMBER
SET
SWITCH
AT
MA RANGE OF
POWER UNIT ASSY.
THERMOCOUPLE TYPE
AND LENGTHS
LOW
HIGH
807, A814, A824, A854
A864, 1870, 871
Any Basoid Valve
Basotral Valve GAl, GAW,
GAX, GAZ, GDT, GDX,
GKT, GKX, GHZ
Actrol Valve MAY, MAVR
300
MA
80
275
No. 80 or Na. 88
up to 54" mcI.
No. 87
55" to 72" mcI.
X5* Power Units for
above Baso Valves
300
MA
60
200
No. 87
73" to 144" mcI.
No. 87 61" to
144" mcI.
X6* Power Units for
above Baso Valves
300
MA
40
135
No. 87
145" to 240" mcI.
812G. 815C, 815G
A817E, 819G, 819H,
0
829G, D832G,
1D832Q, A838, A843G,
ui
843G. B844G, B846G
300
MA
50
145
No. 88E or No. 88H
with H Pilot
12" to 72"
A844
Q.
300
MA
90
160
No. 80 or No. 88
12" tg 24" Pilot to
Junction Black
A848, 855 Switch with
Junction Black and two
SI
6" lead connectors
300
MA
105
175
No. 80 or No. 88
12" to 24", No. 87D
up to 36" Pilot to
Junction Block
BASO MODEL
NUMBER
SET
SWITCH
AT
PULL
IN
DROP
OUT
THERMOCOUPLE TYPE
AND LENGTHS
860, 861
900
MA
300
MA
400
85-200
No. 80 or No. 88
to4O"or
No. 87 to 48"
4
960, 961 Switch
'
MCS1O4
900
MA
300
MA
425
90-215
No. 97 to 96"

Advertisement

loading