THIS TEST KIT COMBINES THE FOLLOWING FUNCTIONS:
A MILLIVOITMETER with 3 direct reading scales for checking open
circuit millivoltage of Thermocouple Leads and Pilot Generators.
A PERFORMANCE TESTER with a source of power for holding Baso
controls open for taking open circuit millivolt readings of the Thermo-
couple while the main burner is in operation.
A MILLIAMMETER with 3 direct reading scales for checking current
dropout range of Baso Power Unit Assemblies.
A CONTINUITY TESTER for detecting a broken or open circuit.
MODEL 120 BASO TEST KIT GENERAL INSTRUCTIONS
When using meter, plugs must be inserted into jacks firmly and squarely.
Adapters
and nuts of thermocouples must be clean and tight. Any meter fluctuation caused by
the movement of these parts shows loose connections. Poor connections will cause
false readings. Replace batteries with positive or center terminals up.
WARNING
Do not use this meter to measure any outside current.
Do not use this meter to measure AC voltages.
This meter
is
designed and calibrated far DC voltages up to 900
MILLIVOLTS only. Any attempt to measure AC current or DC current
over 900 MILLIVOLTS will damage the meter.
Do not operate meter so as to cause needle to swing violently to right
to limit of travel. To prevent violent needle swing, set selector switch
to proper range before attaching test cables.
Please check this
instrument for damage immediately upon arrival
of shipment.