Sharp AR-121E Service Manual page 97

Hide thumbs Also See for AR-121E:
Table of Contents

Advertisement

AL-1000/1010
Main code
Sub code
24
7
Drum counter clear
(Operation/Procedure)
When the START key is pressed, the drum counter value is reset to 0.
13
Scanner counter clear
(Operation/Procedure)
When the START key is pressed, the scanner counter value is reset to 0.
25
1
Main motor operation check
(Operation/Procedure)
When the START key is pressed, the main motor is rotated for 30 sec.
To save toner consumption, the different operations are executed depending on installation of the developing unit.
. When the developing unit is installed, the developing bias, the main charger, and the grid are also outputted.
. When the developing unit is not installed, only the motor is rotated.
* Do not turn on the door open/close switch forcibly to execute this simulation.
10
Polygon motor operation check
(Operation/Procedure)
When the START key is pressed, the polygon motor is operated for 30sec.
26
1
Manual paper feed section setting
(Operation/Procedure)
1. When this simulation is executed, the currently set bypass code number is displayed.
2. Enter the code number corresponding to the bypass and press the START key, and the setting will be changed.
6
Destination setting
(Operation/Procedure)
1. When this simulation is executed, the currently set destination code number is displayed.
2. Enter the code number corresponding to the destination and press the START key, and the setting will be changed.
7
Machine conditions check
(Operation/Procedure)
When this simulation is executed, the current machine setting is displayed.
Code number
0
Single bypass
1
Code number
0
1
2
Japan AB series
CPM
Copy quantity display
10cpm
12cpm
15cpm
Contents
Bypass
Multi bypass
Destination
Inch series
EX AB series
10
12
15
10-5