  • Page 1 EQUIPMENT O P E R A T I O N M A N U A L Loctite ® Series 9000 Rotospray Pump 983330...
  • Page 2: Table Of Contents

    Table of Contents Warnings & Precautions ......2 Introduction ........3 Items Supplied .
  • Page 3: Warnings & Precautions

    Warnings and Precautions • OBSERVE ALL WARNINGS. READ and UNDERSTAND all instructions in the manual before attempting to install and operate this equipment. • This equipment has been designed and tested for use with Loctite ® anaerobic products. • DO NOT USE equipment for other than intended use. •...
  • Page 4: Introduction

    The Loctite Series 9000 Rotospray Pump is pneumatically operated and needs a 4-way pneumatic valve to control the pneumatic signals. The Loctite Series 9000 Rotospray Pump is usually part of a system that consists of the following components: 1. A gravity reservoir to supply product to the Loctite Rotospray Pump.
  • Page 5: Installation Instructions And Required Controls

    Installation Inspection Before Installation The Loctite Rotospray Pump was inspected before shipment. Check the items in the shipping container against the list on Page 3 of this Manual. After removing the items from the shipping container inspect them for visible damage. Promptly report any damaged or missing parts to both the shipper and your Loctite representative.
  • Page 6: View Of Rotospray Pump With Components Labeled

    Installation, cont. STROKE ADJUSTER KNOB CONTROL AIR "DISPENSE" PORT CONTROL AIR "RETRACT" PORT PRODUCT INLET FITTING LOCKING RING PRODUCT OUTLET FITTING PUMP ASSEMBLY (983117) ACTUATOR ASSEMBLY (983116) MOUNTING BRACKET (983335) Fig. 1 View of the Pump with Component Labeled.
  • Page 7: Theory Of Operation

    Theory of Operation The Loctite Series 9000 Rotospray Pump is a pneumatically-operated piston pump. It has a single ball type check valve at the outlet and a flooded inlet. The piston stroke is adjustable to control the amount of product dispensed.
  • Page 8: Operation

    Operation Priming the Pump (first time use) 1. Set the pump stroke to maximum. 2. Move the pump piston to the fully retracted position. 3. Fill the reservoir with product. 4. Disconnect the 3/8-inch OD tube from the pump inlet. 5.
  • Page 9: Maintenance

    Maintenance Routine 1. Inspect air tubing, product tubing, and fittings for cracks, kinks or breaks and replace, as required. 2. Drain the air line filter bowl, if necessary. Idle Time 1. If the pump is in daily use, you do not need to service the pump or product tubing to prevent product curing unless a contaminant is introduced into the system.
  • Page 10: Pump Replacement Procedure

    Maintenance, cont. Replacing The Pump Or Actuator Module The rotospray pump consists of a pump module (part no. 983117) and an actuator module (part no. 983116). In most cases, the pump module is the one replaced. WARNING: Failure to correctly change out the pump module(s) will result in DAMAGE. No tools are required to connect or disconnect the pump from actuator.
  • Page 11: Troubleshooting

    Troubleshooting Possible problems and solutions for the Series 9000 Rotospray Pump. Problem Pump does not dispense product and the Stroke Adjuster Knob does not move when the pump is cycled. Pump does not dispense product and the Stroke Adjuster Knob moves very slowly when the pump is cycled.
  • Page 12: Replacement Parts And Assemblies

    Replacement Parts and Assemblies The following is a list of recommended parts or assemblies that may be required to service the Series 9000 Pump: Item Description Pump assembly Actuator Assembly Tubing 1/4-inch OD poly (for pump outlet). Tubing 3/8-inch OD poly (for pump inlet).
  • Page 13: Information On Pump Rebuilding Program

    Series 9000 Pump Rebuilding Program The Series 9000 Pump is not field serviceable. Our rebuilding process ensures that the pump is free of contaminants and assembled to proper specifications reducing the possibly of a premature failure or unsatisfactory performance with Loctite products.
  • Page 14: Specifications

    Specifications 2.50 2.50 2.06 4.20 1.63 REF. 1.50 1.88 DIAMETER .34 DIAMETER 7/16 HEX 9.15 1.35 DIAMETER Fig. 4 Dimensions...
  • Page 15: Utilities Required

    Two Cycle per second maximum. Amount of product dispensed per stroke: Minimum = 0.02 cc. Maximum = 0.40 cc. Weight: 1.7 lbs. Calculated Pressure Ratio for Loctite Part No. 983330 Series 9000 Rotospray Pump: Item Pump Calculated Pressure Ratios Air cylinder diameter Device diameter 1.125 inch...
  • Page 16: Warranty

    Loctite expressly warrants that all products referred to in this Instruction Manual under Loctite Series 9000 Rotospray Pump 983330 (hereafter called “Products”) shall be free from defects in materials and workmanship. Liability for Loctite shall be limited, at its option, to replacing those...
  • Page 17 Loctite Americas 1001 Trout Brook Crossing Rocky Hill, CT 06067-3910 Loctite Corporation One Northfield Plaza, 5600 Crooks Rd. Suite 105 Troy, Michigan 48098 Loctite Canada Inc. 2225 Meadowpine Blvd. Mississauga, Ontario L5N 7P2 Loctite Company de México, S.A. de C.V. Calzada de la Viga s/n, Fracc.