60 kW
Standby Power Rating
60 kW 60 Hz
STANDARD EQUIPMENT
All input connections in one single area
High coolant temperature shutdown
Low oil pressure shutdown
Low coolant level automatic shutdown
Overspeed automatic shutdown
Crank timer
Exercise timer
Oil drain extension
Cool flow radiator
Closed coolant recovery system
UV/Ozone resistant hoses
Watertight state of the art electrical connectors
FEATURES
Innovative design and fully prototype tested
UL2200 Listed
Solid state frequency compensated
voltage regulator
Dynamic and static battery charger
Sound attenuated acoustically designed enclosure
Quiet test for low noise level exercise
Acoustically designed engine cooling system
High flow low noise factory engineered exhaust system
Liquid Cooled Gas Engine Generator Sets
Mainline circuit breaker
Radiator drain extension
Battery charge alternator
2 Amp static battery charger
Battery and battery cables
Battery rack
Fan and belt guards
Isochronous governor
Flex fuel line
Hour meter
State of the art digital control system with R100 digital
control panel
Watertight electrical connectors
Rodent proof construction
High efficiency, low distortion Generac designed
alternator
Vibration isolated from mounting base
Matching Generac transfer switches engineered and
tested to work as a system
All components easily accessible for maintenance
Electrostatically applied powder paint
Model Numbers: 05649
05650
GENERAC 2.4L ENGINE
Turbocharged/Aftercooled
Gaseous Fueled

Advertisement

loading

Summary of Contents for Guardian 05649

  • Page 1 Vibration isolated from mounting base • Matching Generac transfer switches engineered and tested to work as a system • All components easily accessible for maintenance • Electrostatically applied powder paint Model Numbers: 05649 05650 GENERAC 2.4L ENGINE Turbocharged/Aftercooled Gaseous Fueled...
  • Page 2: Engine Specifications

    APPLICATION & ENGINEERING DATA GENERATOR SPECIFICATIONS TYPE ...Synchronous ROTOR INSULATION ...Class H STATOR INSULATION ...Class H TOTAL HARMONIC DISTORTION ... <5% TELEPHONE INTERFERENCE FACTOR (TIF) ...<50 ALTERNATOR OUTPUT LEADS 3 PHASE ... 4 wire BEARINGS ... Sealed Ball COUPLING ... Flexible Disc LOAD CAPACITY (STANDBY RATING) ...
  • Page 3 60 kW OPERATING DATA KW RATING ENGINE SIZE GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208/240 3-phase ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle 25% of rated load 50% of rated load 75% of rated load...
  • Page 4 Installation Drawing Ref. No. 0F9577 INSTALLATION LAYOUT Generac Power Systems, Inc. • P .O. Box 8, Waukesha, WI 53187 • generac.com ©2008 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0178490SBY/Printed in U.S.A.06.08, rev: 10.08 VOLTS / AMPS LUG SIZE...