Configuring For Wsp-038 With Wassp V123; Appendix; Appendix A - Interconnections; Appendix A.1 Drx Rs422-A To Satellite Compass - Wassp WASP-038 Installation Manual

Table of Contents

Advertisement

4.3.2. Configuring for WSP-038 with WASSP V123

1.
With the system full connected with all sensors powered on open the
WEBPAGES.
2.
Select
CONFIGURATION
and open the
AVAILABLE PRESETS
3.
Under
WASSP V123 WITH
select
WSP-038
and select LOAD.
4.
Setup the sensor offsets
under the
SENSOR
tab,
following the instructions in
the DRX Installation Manual.
5.
Setup the Sensor Biases
under the
DATA SETUP
tab,
following the instructions in
the DRX Installation Manual.
wassp.com
Page 14 of 24
WSP-038 IMU INSTALLATION MANUAL
DRX SETUP
PRESETS
tab.
Doc: WSP-038 IMU INSTALLATION MANUAL
Version: 1.4 December 2019
WSP-038 IMU INSTALLATION MANUAL

5 APPENDIX

APPENDIX A - INTERCONNECTIONS

APPENDIX A.1 DRX RS422-A TO SATELLITE COMPASS

RS422-A
Connector
on DRX
PIN
Function
1
PPS (AUX)
2
RxD B
View: Looking into the socket on the
DRX. Wiring view of cable side on plug.
3
RxD A
4
TxD B
5
TxD A
6
GND Isolated
7
8
9-30V+
9
9-30V-
Satellite Compass Connection for Furuno SC:
WASSP IF-SC
RS422-A
(Optional)
1
PPS (AUX)
Blue / White
2
RxD B
DRX Rx + (B)
White / Blue
3
RxD A
DRX Rx - (A)
4
TxD B
5
TxD A
6
GND Isolated
7
8
9-30V +
9
9-30V -
Satellite Compass Connection for WASSP V123:
WASSP IF-SC
RS422-A
(Optional)
Red / Blue
1
PPS (AUX)
PPS +
Blue/ White
2
RxD B
DRX Rx + (B)
White / Blue
3
RxD A
DRX Rx - (A)
4
TxD B
PPS -
5
TxD A
POWER +
6
GND Isolated
POWER -
7
8
9-30V +
9
9-30V -
wassp.com
Doc: WSP-038 IMU INSTALLATION MANUAL
Version: 1.4 December 2019
Marker identifies pin 1.
1
7
9
2
6
8
3
4 5
Furuno SC
TxD B
TxD A
WASSP V123
Orange
PPS
Yellow
TxD +
Yellow / Black
TxD -
Orange / Black
PPS GND
Red
PWR +
Black
PWR -
Page 15 of 24