Keiser ABDOMINAL AIR250 Operation Manual

Keiser ABDOMINAL AIR250 Operation Manual

Hide thumbs Also See for ABDOMINAL AIR250:

Advertisement

Quick Links

STRENGTH
| CARDIO | FUNCTIONAL
AIR250
ABDOMINAL
MODEL 2721XX
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ABDOMINAL AIR250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Keiser ABDOMINAL AIR250

  • Page 1 STRENGTH | CARDIO | FUNCTIONAL AIR250 ABDOMINAL MODEL 2721XX OPERATION MANUAL...
  • Page 2: Table Of Contents

    Distribution and copying of this document, use and communication of its contents is not permitted without written authorization from Keiser Corporation. The content of this document is furnished for informational use only, may be subject to change without notice, and should not be construed as a commitment by Keiser Corporation.
  • Page 3: General Information

    Air250 Abdominal after reading this manual, our Keiser Customer Support team will be happy to assist by telephone at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at service@keiser.com.
  • Page 4: Important Safety Information

    AIR250 ABDOMINAL OPERATION MANUAL IMPORTANT SAFETY INFORMATION It is the sole responsibility of the purchaser of Keiser Corporation 14. Never perform Power Test without a proper warm-up. This equipment to instruct all individuals, whether they are the end- high resistance/high-speed test should only be performed user or supervising personnel, on proper usage of the equipment.
  • Page 5 SAFETY AND NOTIFICATION LABELS 002721XX 888888-88888 SEAT SEAT Maintain and do not remove safety or notification labels for any reason. They contain important information. If unreadable or missing, contact Keiser Corporation for a replacement (see back cover for contact information).
  • Page 6: Technical Specifications

    AIR STORAGE TANK POWER The equipment contains an air storage tank (air accumulator) • 1.5V D Alkaline Batteries (quantity 2, Keiser PN 966500) with the following operating parameters: • 3V CR2032 Lithium Coin Cell Battery (quantity 1) Permanently attached, not serviceable. Contact Keiser Customer Support for service.
  • Page 7: Installation And Placement

    Compressor ON (allow the Compressor to build up to a minimum of 100 psi / 1/4-inch QD 6.89 bar; Keiser Compressor and Keiser Air System not included, sold separately) Keiser 2. Connect the 1/4-inch Quick Disconnect (QD) from...
  • Page 8: Operation

    AIR250 ABDOMINAL OPERATION MANUAL OPERATION EQUIPMENT OVERVIEW Figure 5. Air250 Abdominal Increase/Decrease (+/-) Thumb Buttons Seat Power Display Processor Box Cylinder Exercise Arm Air Tank Chest Pad Anti-Slip Steps eChip Quick Disconnect (QD) with Tube Instruction Placard (not shown) Locking Pin (Seat Height Adjustment)
  • Page 9: 09_Power Display

    AIR250 ABDOMINAL OPERATION MANUAL POWER DISPLAY SEAT SEAT When using the eChip, ensure that it is fully inserted into the slot as shown. Figure 6. Power Display Overview CAUTION Rate monitoring systems may be inaccurate. Over Use of the exercise Target program requires medical exercising may result in serious injury or death.
  • Page 10: 10_Display Features

    The eChip collects workout data and can store up to 24 separate equipment models (up to 4 equipment position settings per model) and up to 240 separate workout sets across Keiser Air and Infinity Series. Designed as an electronic replacement for the hand-written exercise card, the eChip enables recall and set-up of the exercise equipment upon the next workout.
  • Page 11: 11_Proper Operation Check

    Immediately replace damaged, worn, or broken parts. Do not use the Air250 Abdominal until all repairs have been completed and tested by a Keiser-certified technician. * “Lo-bA” = Batteries are low, replace immediately. If batteries are dead (depleted), the Power Display remains blank (see...
  • Page 12: 12_How To Use The Air250 Abdominal

    AIR250 ABDOMINAL OPERATION MANUAL HOW TO USE THE AIR250 ABDOMINAL Adjust the Seat height to allow the Chest Pads to rest firmly against your upper chest. 2. Sit with your back supported by the Seat backrest, feet on the floor (or on the Anti-Slip Step). 3.
  • Page 13 AIR250 ABDOMINAL OPERATION MANUAL HOW TO USE THE AIR250 ABDOMINAL (CONTINUED) CAUTION • Consult your physician before beginning any exercise • If you feel pain, faintness, or are unable to maintain program. good form, stop immediately. • This equipment should only be used with proper •...
  • Page 14: 14_Power Test

    TEST PROTOCOL — The Power Test (KEISER Six-Rep Test) is used to determine the resistance at which you achieve MAXIMUM POWER. The test consists of two sets: Three repetitions Three repetitions...
  • Page 15: Maintenance

    IMPORTANT: Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint finish and cause corrosion. Use only mild soap/detergent (neutral, non-caustic) to clean. Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your Air250 Abdominal (see back cover for contact information).
  • Page 16: 16_Battery Replacement

    AIR250 ABDOMINAL OPERATION MANUAL BATTERY REPLACEMENT Do not operate the equipment during battery replacement procedure. “Lo-bA” = Batteries are low, replace immediately. NOTE: If batteries are dead (depleted), the Power Display remains blank. To replace the batteries, refer to Figure 10 and follow the instructions below (no tools required).
  • Page 17: 17_Annual Maintenance

    THE AIR IN THE EQUIPMENT (“— ” THUMB BUTTON) BEFORE PERFORMING ROUTINE MAINTENANCE. Figure 11. Annual Routine Maintenance Illustration Contact Keiser Customer Support for replacement part(s) order, or for any matters regarding the safe operation of your Air250 Abdominal (see back cover for contact information).
  • Page 18: Regulatory And Compliance Notices

    AIR250 ABDOMINAL OPERATION MANUAL REGULATORY AND COMPLIANCE NOTICES Standards ISO/EN 20957-1 Accuracy Class A (High accuracy) and Usage Class S (Studio, commercial use); IEC/EN 60601-1 and IEC/EN 60601-1-2. Marks SAFETY NOTIFICATIONS Displayed watts testing parameters: “Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
  • Page 19: 19_Electromagnetic Compatibility (Emc)

    Wear parts: After being replaced, wear parts must be disposed of according to country-specific waste laws. If you have any questions about equipment disposal, please contact your local dealer or Keiser Customer Support (see back cover for contact information).
  • Page 20: Warranty Statement

    View or print your Air250 Abdominal warranty online at keiser.com/support/warranty. If you have any questions about your warranty, please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at service@keiser.com.

Table of Contents