Pressure Relief Procedure - Graco GC-1402 User Manual

Low emission external-mix dispense gun
Table of Contents

Advertisement

Pressure Relief Procedure

To relieve fluid and air pressures:
1. Push down Yellow slide valve, P/N 21402-00 to bleed
off air to system.
2. Open P/N 21228-00 on catalyst pump to recirculation
position.
3. Open P/N 21192-00 on bottom of material pump.
12
4. Verify the trigger lock is engaged.
Daily Maintenance
It is recommended that the following service be per-
formed on a daily basis.
1.
Remove gear cover, p/n: 23798-00, and inspect valves
to see if there is any leakage, on the top or bottom
side of the valves. if there is leakage, with pressure
relieved, tighten packing nut, p/n: 23764-00 1/8 to 1/4
turn until leak stops. Verify that there is no leakage.
4.
Maintain a reasonable stock level of "wear" items
such as Packings, Seals and O-Rings
5.
If dispense gun is leak tested, be sure to dry gun
thoroughly.
6.
Never leave dispense gun immersed in any liquid.
GC-1402E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc-1402eGc-1402fFormula x chop 23750-03

Table of Contents