W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
Symptom
Does not cool
The room cannot be cooled suffi ciently.
Airfl ow
The air from the indoor unit smells strange.
Sound
Cracking sound is heard.
"Burbling" sound is heard.
Mechanical sound is heard from the indoor
unit.
The sound of water fl owing is heard.
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type
fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected
device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
Explanation & Check points
• Is the temperature setting appropriate?
• Is the fan setting appropriate? Please change fan speed to High
or Super High.
Page 9
• Are the fi lters clean?
Page 13
• Is the fan or heat exchanger of the indoor unit clean?
• Are there any obstacles blocking the air inlet or outlet of the in-
door or outdoor unit?
• Is a window or door open?
• When a ventilation fan or a gas cooker is used in a room, the
cooling load increases, resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the cooling effect may not
be suffi cient.
• It may take a certain time to reach the setting temperature or may
not reach that depending on the size of the room, the ambient
temperature, and the like.
• Are the fi lters clean?
Page 13
• Is the fan or heat exchanger of the indoor unit clean?
• The unit may suck in an odor adhering to the wall, carpet, furni-
ture, cloth, etc. and blow it out with the air.
• This sound is generated by the expansion/contraction of the front
panel, etc. due to change in temperature.
• This sound is heard when the outside air is absorbed from the
drain hose by turning on the range hood or the ventilation fan,
making water fl owing in the drain hose to spout out.
This sound is also heard when the outside air blows into the drain
hose in case the outside wind is strong.
• This is the switching sound in turning on/off the fan or the com-
pressor.
• This is the sound of refrigerant or condensed water fl owing in the
unit.