Download Print this page

Seco SC-SDCB102 Manual page 4

Control panel for sliding gate motors

Advertisement

Available languages

Available languages

SC - SDCB102
Control Panel for Sliding Gate Motors
3.
P-P/DIS-OP
(Maintaining Hydraulic Motor Pressure)
The control unit will send a closing command to motor every 2 hours for 2
seconds to keep Hydraulic motor pressure tighten .
Press [SEL] key brief until [P-P/DIS-OP] LED flash , press [SET] key brief.
[P-P/DIS-OP] LED light on , enable motor hydraulic pressure maintenance.
[P-P/DIS-OP] LED light off , disable motor hydraulic pressure maintenance.
External Menu 2 LED indicated:
T.PAUSE
[T.PAUSE] and [T.MOTOR]
LEDS flash synchronous
T.MOTOR
LAMP/CORT
Input SW = START
P-P/DIS-OP
Closing disable input off
Soft-start off
CODE.PEDE
1 second reverse
CODE.START
1. CODE.START
The control unit set the motor reverse motion normally about 1 second ,
to increase reverse speed , it can set about 0.5 second .
Press [SEL] key brief until [CODE.START] LED flash, press [SET] key brief.
[CODE.START] LED light on , setting 0.5 second reverse motion .
[CODE.START] LED light off , setting 1 second reverse motion .
3.
P-P/DIS-OP
Press [SEL] key brief until [P-P/DIS-OP] LED flash, press [SET] key brief.
[P-P/DIS-OP] LED light on , enable command disable during closing.
[P-P/DIS-OP] LED light off , command enable during closing.
SYSTEM RESET :
To restore all the default configuration , press and hold [SEL] and [SET]
keys together , all function LEDS will light on then light off , system reset
procedure finish .
OW VOLTAGE INPUT DIAGNOSTICS :
The control unit have 4 LEDS near the connector of low voltage input , monitor the
status of input status .
L
When the input close , correspond LED will light on .
When the input open , correspond LED will light off .
4
R
LED OFF
[T.PAUSE] and [T.MOTOR]
LEDS flash synchronous
Input SW = PHOTO
Closing disable input on
Soft-start on
0.5 second reverse
(Reverse Time 1s/0.5s select)
(Command disable during closing)
4. LAMP.CORT
Electronics brake means control unit reduces the forward inertia when
the gate ready to stop or reverse motion .
Press [SEL] key brief until [LAMP.CORT] LED flash, press [SET] key brief.
[LAMP.CORT] LED light on , enable electronics brake.
[LAMP.CORT] LED light off , disable electronics brake.
Enter External Menu 2 :
When control unit current in external menu 1 , press and hold [SET]
key over 5 seconds , the [T.PAUSE] and [T.MOTOR] LEDS flash
synchronous , now enter External Menu 2.
LED ON
Exit to Standby Menu :
When enter External Menu 2 , over 30 seconds without [SEL] or
[SET] key press , control unit will return back to standby menu .
2.
CODE.PEDE
Soft start means motor at every start movement , control unit will given
the power gradually to motor , from minimum to maximum in the first
2 seconds of operation .
Press [SEL] key brief unitl [CODE.PEDE] LED flash, press [SET] key brief
[CODE.PEDE] LED light on , enable motor soft start .
[CODE.PEDE] LED light off , disable motor soft start .
4. LAMP.CORT
User can select the input switch is normal open (NO) contact connect to
[11-12] START and COM , or normal close (NC) contact connect [12-13]
PHOTO and COM .
Use NC contact , when motor opening and give command , gate will stop
and reverse for a short distance .
Press [SEL] key brief until [LAMP.CORT] LED flash, press [SET] key brief.
[LAMP.CORT] LED light on , select input SW is PHOTO .
[LAMP.CORT] LED light off , select input SW is START .
Photocells Connec�on
8
24V
(Electronics Brake)
(Soft-Start)
(Input SW is START or PHOTO)
9
11 12
COM
NC
C
0
0
24V
24V
PH

Advertisement

loading