Download Print this page

SDC EntryCheck 918W Installation Instructions page 3

Advertisement

SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
FACTORY DEFAULTS
Master Programming Code.........................................123456
Keypad Output Mode......................................26-bit Wiegand
Keypad Output Site Code...............................................000
Beeper Sounds When Key Pressed..................................Yes
Beeper Volume........................................................Normal
Keypad Backlight Mode..........................30 sec after activation
Keypad Timeout..........................................................5 sec
918W OPERATION
The 918W EntryCheck™ keypad will emulate a reader credential.
Entering a 'card' number followed by '#" will transmit the
programmed facility code plus the card number as a 26-bit
Wiegand output. The card number entered must be > 0 and <
65,535.
For example, if the default Facility Code has been changed to
123, pressing 1234 + #, will send '12301234' as the complete
card number.
ERROR ANNUNCIATION (Wiegand Mode only)
Keypad Action
Key press timeout (in standby)
0, or number >=  65535 is entered Red LED flash w/ beep (x3)
* is entered
Master Code error
BASIC PROGRAMMING
While the 918W is in Programming Mode the yellow indicator
will blink slowly.
After a programming function is selected, the yellow indicator
will flash rapidly while the keypad is waiting for user input data.
You will have 5 sec. between programming commands once a
function is selected. The green indicator will light if the data is
accepted. The red indicator will light if any programming data
is entered incorrectly, and the function will have to be fully re-
entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is
used to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
Exiting Programming Mode
Press:
The red indicator will light after exiting Programming Mode
Note: The 918W will automatically exit Programming Mode after
2 minutes of inactivity
Changing the Beeper Sound Level
The Keypad's beeper can be set to normal or low level.
Remove jumper JP1 to reduce beeper sound level.
See Page 2 for the location of JP1.
P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918W
Indication
Double Beep
Red LED flash w/ beep (x3)
Red LED flash w/ beep (x3)
**
#
Rev A
11-21
PROGRAMMING FUNCTIONS
Enter Programming Mode before performing any of the following
functions.
Changing the 6-Digit Master Programming Code
It is recommended that the Master Programming Code be
changed after the installation is finalized.
Press: 98 # Master Code # Master Code #
Master Code = The new 6-digit Master Programming Code
Beep Sounds on Keystrokes
Selects whether or not the keypad beeps as each key is pressed.
Press: 40 # Sound #
Sound=1 for Yes, =0 for No
Selects mode for Keypad LED Backlight
Selects whether or not the keypad back light stays OFF, lights for
30 seconds when activated or stays ON.
Press: 52 # Output #
Output = 0, Light always OFF
= 1, 30 sec light when activated (default)
= 2, Light always ON
Change Facility (Site) Code
Selects the Site Code when using the Keypad in Weigand Mode.
Press: 82 # Site Code #
Site Code = New 3-Digit Site Code (000-255)
RESETTING THE KEYPAD READER
Master Reset
Resets all programming options.
NOTE: The Master Code will NOT be reset.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the * and # keys.
STEP 3 Apply power to the keypad, continue holding the keys
down until the red indicator starts flashing
STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the yellow
indicator will go out.
Resetting the Master Code
STEP 1 Remove the 918W from the wall and disconnect
power from the keypad.
STEP 2 Locate & remove jumper JP2. Reference page 2.
STEP 3 Re-apply power. You will get a single beep and
the yellow LED will flash momentarily.
STEP 4 Replace jumper on JP2. The Master Code is now
123456.
Page 3
Default: Yes
Default: 30 Secs.
Default: 000

Advertisement

loading