Means Of Protection (Mops) - OEM PCA-20 User Manual

Capacitor charging modules
Table of Contents

Advertisement

Means of protection (MOPs)

Declared MEANS OF PROTECTION (to be confirmed with test reports for every
particular part number):
Path
Insulation of Input wires
Input-to-chassis
Input-to-input (opposite
polarity before fuses)
Mains part-to-chassis
Mains part-to-secondary
circuits
Besides, module must be protectively grounded, which is considered as 1x MOPP.
MOPs
2x MOPP @ 340Vpk
2x MOPP @ 340Vpk
1x MOOP @ 340Vpk
1x MOPP @ 420Vpk
1x MOOP @ Working
voltage (depends on
modification)
Path
Input-to-Output
Input-to-Interface
Output-to-chassis
Output-to-Interface
Insulation of Output wires
MOPs
1x MOOP @ Working
voltage (depends on
modification)
1x MOOP @ Working
voltage (depends on
modification)
Output negative is
intentionally connected
to the chassis
Interface is galvanically
connected to the output
2x MOPP @ Output
voltage (depends on
modification)
14