Eastwood MIG 90 Assembly And Operating Instructions Manual page 9

Table of Contents

Advertisement

MIG 90 WELDER SET-UP
The Eastwood MIG 90 is factory set-up for MIG Welding use with Solid Wire
(0.023" included) and Shielding Gas (not included).
This set-up includes the proper polarity (DCEP) and the Drive Roller set for
0.023" (0.6 mm).
The procedure for configuring to Flux Core use is covered further on in this Manual.
ASSEMBLE THE FACE SHIELD
• Slide the #11 Glass Shade [G] Lens under the Retaining Clips at the inside of
the Shield [F] (FIG 4).
• Snap the Handle [H] into its receptacle from the Back of the shield seating it
fully and firmly (FIG 4).
• Press the Handle Retaining Plug [J] into the corresponding shape from the
front (FIG 5).
INSTALLING THE GROUND CABLE AND CLAMP
• Locate the 7 ft. Ground Cable/Clamp Assembly [B] and connect the plug on
the brass end to the Negative Ground Cable Connection (–) on the Welder [f].
Align the key of the brass ferrule with the notch of the receptacle at the 12:00
position, insert the plug and twist Clockwise 1/2 turn until it is tight (FIG 6).
To order parts and supplies: 800.343.9353 >> eastwood.com
FIG. 4
FIG. 4
FIG. 5
FIG. 5
FIG. 6
FIG. 6
9