Advertisement

Quick Links

homee CentronicPLUS Cube
en
Assembly and Operating Instructions
CentronicPlus extension for the homee Brain Cube
4036 630 197 0     07.09.2021   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the homee CentronicPlus Cube and is the answer not in the manual?

Questions and answers

Summary of Contents for Becker homee CentronicPlus Cube

  • Page 1 CentronicPLUS Cube Assembly and Operating Instructions CentronicPlus extension for the homee Brain Cube 4036 630 197 0     07.09.2021    Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com...
  • Page 2: Table Of Contents

    Table of contents General information ....................  3 Licensing information for open source software.............  5 Warranty ...................... 6 Safety instructions .................... 7 Intended use ......................  9 Assembly and commissioning ................ 11 Cleaning...................... 12 Technical data .................... 12 Simplified EU declaration of conformity...............  14 2 - en...
  • Page 3: General Information

    General information You can use this control uni to establish a connection between the control unit and compatible receivers. This device is exceptionally easy to use. Please follow these Assembly and Operating Instructions when installing and setting up the device. 3 - en...
  • Page 4 Explanation of pictograms CAUTION indicates a hazardous situation CAUTION which, if not avoided, could result in injury. ATTENTION indicates measures that must be ATTENTION taken to avoid damage to property. Denotes user tips and other useful informa- tion. 4 - en...
  • Page 5: Licensing Information For Open Source Software

    App or can be downloaded at www.becker-antriebe.com/licenses. Written request for the licence texts: Becker-Antriebe will, on request, provide the licence texts for the licensed software being used at cost price, either on a USB stick or a similar data carrier. Please send an email to the following email address for more information: licenses@becker‑antriebe.com...
  • Page 6: Warranty

    Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions.
  • Page 7: Safety Instructions

    Safety instructions General information • Please keep the instruction manual safe! • Only use in dry rooms. • Keep people out of the system’s range of travel. • Keep children away from control units. • Observe all pertinent country-specific regulations. •...
  • Page 8 • Switch the control unit off immediately if the housing of the con- trol unit is damaged, or if liquids have penetrated. Attention • Do not let any objects fall onto the control unit. • Wait until the control unit has adjusted to the ambient temperat- ure before using it.
  • Page 9: Intended Use

    Intended use The control unit in this manual must be combined with a homee Brain Cube and must only be used indoors for the control of CentronicPlus-compatible radio drives and ra- dio remote control units. • Please note that radio-controlled systems may not be used in areas with a high risk of interference (e.g.
  • Page 10 • Ensure that the control unit is not installed or operated close to metal surfaces or magnetic fields. • Radio-controlled systems transmitting on the same frequency may cause reception interference. • Note that the range of the radio signal is limited by legislation as well as by design.
  • Page 11: Assembly And Commissioning

    Assembly and commissioning Place the control unit on top of the homee Brain Cube or an existing extension cube so that they lock together. To start using it with the homee Brain Cube, install the homee app from homee GmbH on your smartphone and follow the instructions on the app.
  • Page 12: Cleaning

    Cleaning Only clean the device with a suitable cloth. Do not use aggressive cleaning agents that may damage the surface. Technical data Control unit homee CentronicPLUS Cube Supply voltage 5 V DC Current consumption < 70 mA Permissible ambient tem- -10°C to +55°C...
  • Page 13 Control unit homee CentronicPLUS Cube Dimensions (H x W x D) 53 x 50.5 x 50.5 mm Weight 68 g Maximum emitted trans- ≤ 25 mW mission power Radio frequency 868.3 MHz The maximum transmitter range on and in the building is up to 15 m, and up to 150 m in the open.
  • Page 14: Simplified Eu Declaration Of Conformity

    Simplified EU declaration of conformity Becker-Antriebe GmbH hereby declares that this radio control system complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following web ad- dress: www.becker-antriebe.com/ce Subject to technical changes without notice.

Table of Contents