Carrier 38BYC Installation And Start-Up Instructions Manual page 5

12 seer split system heat pump
Table of Contents

Advertisement

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Accumulator
Compressor Start-Assist
Capacitor and Relay
MotorMaster® Control,
or
Low-Ambient Pressure Switch
Wind Baffle
Unit Risers
Liquid-Line Solenoid Valve
or
Hard-Shutoff TXV
Ball-Bearing Fan Motor
* For tubing line sets between 50 and 175 ft, refer to Application Guideline and Service Manual — Air Conditioners and Heat Pumps.
† For buried line applications, refer to Application Guideline and Service Manual — Air Conditioners and Heat Pumps.
‡ Required for low-ambient controller (full-modulation feature) and MotorMaster® Control only.
DISCONNECT
PER N. E. C. AND/OR
LOCAL CODES
FIELD POWER
WIRING
FIELD GROUND
WIRING
Fig. 8—Line Power Connections
Use furnace transformer, fan coil transformer, or accessory trans-
former for control power, 24v/40va minimum.
NOTE: Use of available 24v accessories may exceed the mini-
mum 40va power requirement. Determine total transformer load-
ing and increase the transformer capacity or split the load with an
accessory transformer as required.
IMPORTANT: Check factory wiring and wire connections to
ensure terminations are secured properly. Check wire routing to
ensure wires are not in contact with tubing, sheet metal, and so
forth.
Step 11—Compressor Crankcase Heater
When equipped with a crankcase heater, furnish power to heater a
minimum of 24 hr before starting unit. To furnish power to heater
only, set thermostat to OFF and close electrical disconnect to
outdoor unit. A crankcase heater is required if refrigerant tubing is
longer than 50 ft.
Step 12—Install Electrical Accessories
Refer to the individual instructions packaged with kits or acces-
sories when installing.
Table 2—Accessory Usage
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(BELOW 55°F)
Yes
Yes
No
Yes
Yes
See low-ambient
Instructions
Recommended
No
Yes‡
CONTACTOR
GROUND
LUG
A91056
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(OVER 50 FT)
Yes
No
No
Yes
No
No
No
See Long-Line
Application
Guideline
No
Step 13—Start-Up
To prevent compressor damage or personal injury, observe
the following:
•Do not overcharge system with refrigerant.
•Do not operate unit in a vacuum or at negative pressure.
•Do not disable low-pressure switch.
In scroll compressor applications:
•Dome temperatures may be hot.
To prevent personal injury wear safety glasses, protective
clothing, and gloves when handling refrigerant and observe
the following:
•Back-seating service valves are not equipped with Schrader
valves. Fully back seat (counterclockwise) valve stem before
removing gage-port cap.
•Front-seating service valves are equipped with Schrader
valves.
Federal Regulations require that you do not vent refrigerant to
atmosphere. Recover during system repair or final unit
disposal.
Follow these steps to properly pumpdown a system and avoid
negative suction pressure.
1. Fully back seat (open) liquid- and vapor-tube service valves.
2. Unit is shipped with valve stem(s) front seated (closed) and
caps installed. Replace stem caps after system is opened to
refrigerant flow. Replace caps finger-tight and tighten with
wrench an additional 1/12 turn.
3. Close electrical disconnects to energize system.
5
REQUIRED FOR
BURIED LINE
APPLICATIONS†
(OVER 3 FT)
Yes
No
Yes
Yes
No
No
No
Yes
No