Problem
Coffee dispensing is re-
peatedly interrupted
and the message
bean container
appears in
the display.
Steam is dispensed in-
stead of water while
preparing hot water or
making tea.
The display is hard to
see or not legible.
The display lights up
but the coffee machine
does not heat up and no
drinks are made.
Possible cause and solution
This is not a fault.
The brew unit has not detected the ground coffee.
Fill the
Certain types of coffee produce a small amount of
coffee when they are ground. Usually the grinder is
set too fine and the amount is set to minimum.
 Confirm the message with OK.
If the display appears with all types of coffee:
 Set the grinder to a coarser setting (see "Grinder
setting").
 Select a larger amount of coffee.
Don't forget to check any drinks changed in "User
profiles".
If the message only appears when dispensing certain
drinks:
 Check the amount of coffee set for this drink (see
"Amount of coffee"). Select a larger amount of
coffee.
 You may also need to set a coarser grinder setting.
It is likely that the wrong altitude has been set.
 Change the altitude settings (
 If necessary, you can also change the temperature
settings for the drinks (
The display brightness has been set too low.
 Change this setting (see "Settings").
The Demo mode for demonstrating the coffee
machine in stores and showrooms has been
activated.
 Deactivate Demo mode (see "Settings").